HVAC Repair — Dual capacitor replaced, refrigerant added
- HVAC
On September 2, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 5233 Greer Avenue, St. Louis, MO 63115.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$700
Trip fee, refrigerant charge (3 lbs max) added, and dual capacitor replaced.
- HVACWork status not resolved
Refrigerant diagnostic app shows R-410A system with suction pressure 144.6 psig, liquid pressure 409.2 psig, actual superheat 24.9°F, and actual subcooling 2.1°F; air side diagnostics show no tools connected.
- HVACWork status not resolved
Refrigerant side diagnostic shows R-410A system with suction pressure 29.1 psig, liquid pressure 166.0 psig, actual superheat 101.3°F (severely elevated), and actual subcooling -31.9°F (abnormal), indicating a likely refrigerant charge or system issue.
- HVACWork status not resolved
Photograph shows Fieldpiece app refrigerant-side measurements for R-410A system: suction pressure 28.9 psig, suction temperature 84.2°F, vapor saturation -17.4°F, actual superheat 101.6°F; liquid pressure 165.9 psig, liquid temperature 90.2°F, liquid saturation 58.3°F, actual subcooling -31.9°F, discharge pressure 165.9 psig.
- HVACWork status not resolved
- HVACWork status not resolved
Central AC is set to cool but producing no air in apartment with forecast temperatures up to 103°F; work order created with habitability priority to inspect and repair ASAP.