Hi, I'm 524 Rebecca Drive. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
524 Rebecca Drive
Across 1 record on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- HVAC · Heat pump replacement quoted but not confirmed complete · Apr 2026$12k
- HVAC · Existing Trane furnace and air handler visible in basement · 2026
- HVAC · Outdoor Trane condenser unit present beside the house · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 524 Rebecca Drive, St. Charles, MO 63301. The amount summary includes $11,935 in estimates; appraisal values and permit-declared valuations are excluded.
HVAC Replacement Estimate — 3-ton heat pump + 80% furnace, declined
- HVAC
Option: Option #1 $11,935 (declined)
Built from Housecall Pro data
- $11,935HVACEstimate for Option #1: Equipment Warranty, Payment Terms, Terms and Conditions, Install Description Full 80% (This quote will include the following, fused disconnect, whip and pad for the), 3 Ton 16 Seer Heat Pump R454B (We Propose to install the following equipment in your home).
- HVACPhotograph shows a Trane XE 90 gas furnace installed in a basement mechanical room, with a black gas supply pipe, red shutoff valve, sheet metal supply plenum, and dual flue/exhaust pipes routed to the ceiling; a yellow EnergyGuide sticker is visible on the lower cabinet.
- HVACPhotograph shows a furnace or air handler unit with sheet metal plenum and flexible duct boot above, flue pipe to the left, and a tape measure stretched across the unit face reading approximately 23 inches at the far end; an expansion tank and copper piping are visible to the right.
- HVACPhotograph shows a gas furnace unit with flue/exhaust piping, sheet-metal supply plenum, and large overhead ductwork in a basement mechanical room; a Carrier documentation sheet is affixed to the adjacent duct panel on the left wall.
- HVACPhotograph shows an outdoor HVAC condenser unit (data plate reads 'XE 1200') installed on a concrete pad close to a brick exterior wall, with refrigerant lines and flexible conduit routed into the structure and a disconnect box mounted on the wall.
- HVACPhotograph shows a vertical two-section air handler/furnace unit connected to a large sheet-metal supply plenum with a round metal flue duct; a stain or residue is visible on the floor at the base of the unit.
- HVACPhotograph shows an aged, weathered dual-fan outdoor condenser unit mounted on a concrete pad adjacent to a brick exterior wall, with refrigerant lines and electrical conduit entering the building and a wall-mounted disconnect box; leaf debris is present around the base.
- HVACPhotograph shows a corroded or aged flexible pipe/hose running along a tile floor beneath a large appliance, with a tape measure indicating approximately 4 inches of clearance at the appliance base; greenish residue or corrosion is visible near the appliance bottom.
- HVACPhotograph shows an HVAC air handler unit with sheet metal duct transition above; a tape measure is extended across the unit width reading approximately 17 inches, with refrigerant lines visible on the left side.
- HVACPhotograph shows a vertical air handler cabinet with copper refrigerant lines, black insulation, condensate drain, and sheet metal ductwork
- HVACPhotograph shows a tape measure extended alongside a sheet metal HVAC air handler or duct enclosure, measuring approximately 25; 29 inches in height; a galvanized sheet metal plenum or duct transition is visible at the base on a white tile floor.
Documented warrantyfive-year / ten-year / twenty-yearFrom estimateView details
What this warranty covers
- parts
· source
“All equipment installed by Contractor comes with a manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an estimate. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.