- HVAC · Air handler and condenser replaced with new plenum and line set · Mar 2026$7.5k
- HVAC · New drain, safety switch, disconnect, and whip also installed · Mar 2026
- HVAC · After-hours service call added refrigerant charge to older system · Jul 2024
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 3 documented records for 5395 Lakewood Terrace, Imperial, MO 63052, dated from July 2024 through March 2026. The amount summary includes $8,095 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Refrigerant Charge — R22 refrigerant charge (2 lb max)
- HVAC
Built from Housecall Pro data
- $595HVACPerformed an after-hours service trip and a refrigerant charge with R22 (2 lb max).
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge service visit, no line items
- HVAC
Built from Housecall Pro data
- HVACInvoice for a service visit on March 10, 2026 with no service lines listed and no charge.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Replacement — Air handler and condenser replaced
- HVAC
Built from Housecall Pro data
- $7,500HVACReplaced hanging air handler and condenser, including new plenum, line set flush, braze and pressure test, triple evacuation and charge, new primary drain and secondary drain safety switch, and replaced disconnect and whip.
- HVACPhotograph shows a wall-mounted HVAC air handler unit with a 14x20x1 air filter installed at the base, flexible metallic electrical conduit, a large round supply duct at the top, copper refrigerant lines, and an EnergyGuide label affixed to the front panel; plumbing supply piping with valves is visible below the unit.
- HVACPhotograph shows an air handler unit installed in a utility closet with a visibly dirty/loaded air filter in place; handwritten label on the unit reads 'Filter: 18x20'.
- HVACdata plate indicates 208/240V 1PH 60HZ power supply, single-circuit heater amps 35.1/40.8, and min. circuit ampacity 46.0/53.7
- HVACPhotograph shows an aged outdoor air conditioning condenser unit installed against vinyl-sided exterior wall, with refrigerant manifold gauges and hoses on the ground beside it and a disconnect box mounted on the wall above; a technician is present alongside the unit.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.