Record 1Public property record

HVAC Refrigerant Charge — R22 refrigerant charge (2 lb max)

  • HVAC

On July 21, 2024, JLM HEATING AND AIR CONDITIONING documented HVAC at 5395 Lakewood Terrace, Imperial, MO 63052.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$595

    Performed an after-hours service trip and a refrigerant charge with R22 (2 lb max).

Record 2Public property record

HVAC Service Invoice — No-charge service visit, no line items

  • HVAC

On March 10, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 5395 Lakewood Terrace, Imperial, MO 63052.

Record date

Available findings

  • HVACCompleted work

    Invoice for a service visit on March 10, 2026 with no service lines listed and no charge.

Record 3Public property record

HVAC Replacement — Air handler and condenser replaced

  • HVAC

On March 13, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 5395 Lakewood Terrace, Imperial, MO 63052.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$7,500

    Replaced hanging air handler and condenser, including new plenum, line set flush, braze and pressure test, triple evacuation and charge, new primary drain and secondary drain safety switch, and replaced disconnect and whip.

  • HVACWork status not resolved

    Photograph shows a wall-mounted HVAC air handler unit with a 14x20x1 air filter installed at the base, flexible metallic electrical conduit, a large round supply duct at the top, copper refrigerant lines, and an EnergyGuide label affixed to the front panel; plumbing supply piping with valves is visible below the unit.

  • HVACWork status not resolved

    Photograph shows an air handler unit installed in a utility closet with a visibly dirty/loaded air filter in place; handwritten label on the unit reads 'Filter: 18x20'.

  • HVACWork status not resolved

    data plate indicates 208/240V 1PH 60HZ power supply, single-circuit heater amps 35.1/40.8, and min. circuit ampacity 46.0/53.7

  • HVACWork status not resolved

    Photograph shows an aged outdoor air conditioning condenser unit installed against vinyl-sided exterior wall, with refrigerant manifold gauges and hoses on the ground beside it and a disconnect box mounted on the wall above; a technician is present alongside the unit.