541 Autumn Bluff Drive
Across 5 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 5 documented records
Fresh House Property Summary
Highlights selected from 5 documented records for this property.
- HVAC · Furnace, air conditioner, coil, and zoning system replaced · May 2026
- HVAC · New Wi-Fi thermostat and PVC condensate piping installed with system · May 2026
- HVAC · Heating maintenance performed; borescope images documented heat exchanger interior · Jan 2026
- HVAC · Cooling season maintenance performed under residential maintenance plan · Apr 2026
- HVAC · Heating season maintenance performed under residential maintenance plan · Oct 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 5 documented records for 541 Autumn Bluff Drive, Ellisville, MO 63021, dated from April 2026 through June 2026. The amount summary includes $16,773.64 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Invoice — No-charge service visit, no line items
- HVAC
Built from Housecall Pro data
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Maintenance Invoice — Heating season maintenance plan visit
- HVAC
Built from Housecall Pro data
- HVACHeating season maintenance performed under the Residential Maintenance Plan.
- HVACPhotograph shows an integrated furnace control board data plate with electrical ratings (24 VAC input, 60 Hz, XFMR SEC. current 450 MA, circ. blower output 14.5 FLA/25 LRA @ 120 VAC), wiring diagram for factory and field wiring, and timing specifications (prepurge 5 sec., interpurge 60 sec., IGN warmup 20 sec., retries 2, recycles 10, auto restart 60 min.).
- HVACPhotograph shows a handheld digital thermometer (model SPK2) displaying a reading of 70.9°F, resting on a gray speckled surface.
- HVACthe background reveals a circuit board and multi-colored wiring harnesses
- HVACPhotograph shows a yellow digital thermometer (SPK2) reading 112°F placed across black and red conduit runs atop silver foil-faced Class 1 duct insulation (SF 686, rated to 200°F).
- HVACPhotograph shows the interior of an open gas furnace panel with a manufacturer data/specification label visible, displaying vent pipe sizing, gas pressure specs, NOx emission limit of 40 ng/J, AHRI Certified and ETL (Intertek) listings, along with associated wiring.
- HVACPhotograph shows a UEI EM152 digital manometer displaying a reading of -3.52 inH2O, being used to measure static pressure near HVAC equipment.
- HVACPhotograph shows a Fasco blower motor (No. 71920333, Type U92B1) with a spec label reading 33-110V, 1.0A, 60-180 Hz, 1500-4700 RPM, Thermally Protected, Sealed Ball Bearing, Class B, installed in an HVAC unit with multicolor wiring visible in the background.
- HVACPhotograph shows a USi EM152 digital manometer clipped to an HVAC unit frame displaying a negative static pressure reading of -1.70 inH2O, with visible blower motor, wiring, and circuit board components in the background.
- HVACPhotograph shows a UEI EM152 digital manometer displaying a reading of -190 inH2O, with probes inserted into what appears to be an HVAC unit (furnace or air handler).
- HVACPhotograph shows a metallic mesh humidifier water panel (evaporator pad) being held up, with visible mineral/scale buildup coating the expanded metal mesh surface.
- UnclassifiedPhotograph shows a hand holding a metal insulation fastener pin with a flat circular metal flange and white plastic collar, with a tool tip visible at top of frame; background appears to be fabric clothing.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Installation — 4-ton A/C, 100k BTU furnace, zoning
- HVAC
Built from Housecall Pro data
- $16,629HVACSupplied and installed a 4-ton American Standard 17 SEER2 two-stage air conditioner, 100,000 BTU variable-speed gas furnace, 4-ton evaporator coil, Sensi Wi-Fi thermostat, PVC condensate piping, pads, disconnect, and an Arzel zoning board and dampers.
- HVACPhotograph shows a high-efficiency condensing gas furnace installed in a basement mechanical room, with dual white PVC flue and combustion-air intake pipes routed through the ceiling, sheet metal supply ductwork above, and a flexible gas line connection at the unit.
- HVACPhotograph shows a high-efficiency gas furnace (tall gray cabinet) with white PVC intake and exhaust flue pipes routed overhead, installed in an unfinished basement mechanical room alongside sheet metal supply ductwork.
- HVACPhotograph shows a high-efficiency condensing gas furnace with white PVC intake and exhaust flue pipes routed overhead, paired with a large air handler/coil cabinet, all installed in an unfinished basement mechanical room.
- HVACPhotograph shows a gray outdoor air conditioning condenser unit mounted on a flat pad adjacent to a house with white vinyl siding, with refrigerant lines, electrical conduit, and a wall-mounted disconnect box visible.
- HVACPhotograph shows an unfinished basement mechanical area with large galvanized sheet-metal ductwork and round elbow transitions at the ceiling, a gray electrical enclosure and disconnect box mounted on a plywood-framed wall, flexible metal conduit and wiring runs overhead, and what appears to be a filter or access panel with mesh screening on the lower portion of the framed enclosure.
- HVACa yellow service reminder sticker is affixed to the plenum, and a water heater is partially visible at upper right
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Cooling Maintenance — Cooling season maintenance performed
- HVAC
Built from Housecall Pro data
- HVACPerformed cooling season maintenance under the residential maintenance plan.
- HVACPhotograph shows a heavily corroded and debris-covered dual-run capacitor inside an HVAC condenser unit, with multiple wire terminals connected at the top and significant rust and dirt accumulation on the capacitor body and terminal area.
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Heating Maintenance — Seasonal heating maintenance
- HVAC
Built from Housecall Pro data
- $145HVACSeasonal heating maintenance performed.
- HVACPhotograph shows a forced air furnace manufacturer data plate with model TUH2C100A9V4VAB, serial 10314JFK7G, date of manufacture 8/2010, rated at 100,000 BTU/HR input and 65,000 BTU/HR output.
- HVACPhotograph shows a borescope camera display screen capturing the interior of a metal component; two curved surfaces meeting at a seam with visible rust-colored staining and dark corrosion concentrated at the junction; screen displays a temperature reading of 122°F.
- HVACPhotograph shows a borescope camera display capturing a close-up of a metal seam with visible rust, corrosion, and a crack or separation along the joint; probe temperature reads 120°F.
- HVACPhotograph shows the interior of a furnace with the access panel removed, revealing multiple heat exchanger burner ports/cells, multi-colored wiring (yellow, green, black, white), flexible armored conduit, and a screwdriver resting on top of the unit cabinet.
- HVACPhotograph shows a borescope screen displaying the interior of an HVAC component with a diagonal crack or debris streak visible on a curved white/gray surface, alongside a circular port opening; ambient temperature reads 118°F.
- HVACPhotograph shows the interior of a furnace with the access panel removed, revealing significant rust and corrosion staining on the heat exchanger/burner area, along with the gas valve control (with ON/OFF and HI/LO markings), flexible metal conduit, and multi-colored wiring harness.
- HVACPhotograph shows the interior of a furnace cabinet with a hot surface igniter (white ceramic rod), a transformer, flexible metallic armored conduit, multi-color wiring harness, and a gas supply pipe running diagonally across the cabinet floor.
- HVACPhotograph shows a borescope camera display capturing an internal view of what appears to be a heat exchanger, with visible rust and brown/orange corrosion concentrated at the seam/junction between two curved metal surfaces; ambient temperature reads 120°F.
- HVACPhotograph shows a borescope camera screen displaying the interior of a corrugated duct, flue, or heat exchanger passage at 118°F, with visible debris or particulate matter on the bottom of the passage; HVAC equipment components are visible in the background.
- HVACPhotograph shows a pipe inspection camera monitor displaying the interior of a pipe with visible rust/orange staining on the pipe walls, moisture droplets, and a pipe joint or fitting centered in the frame.
- HVACPhotograph shows the LCD screen of a pipe inspection borescope camera displaying the interior of a pipe with a visible longitudinal crack or joint separation accompanied by reddish-brown rust and corrosion staining along the seam; probe temperature reads 118°F and device timestamp reads 01-19-2026.
- HVACPhotograph shows a sewer camera monitor displaying the interior of a pipe with a visible crack or break and orange/rust-colored staining radiating from a central dark void, indicating a structural defect in the pipe wall; a distance reading of approximately 192ft and a date stamp of 01-14-2026 are visible on the monitor screen.
- HVACPhotograph shows the interior of a pipe or vessel wall captured on a borescope screen, displaying heavy rust/corrosion staining, a prominent longitudinal crack or seam with dark rust streaking, and a recorded ambient temperature of 116°F.
- HVACPhotograph shows a technician holding a ceramic hot surface igniter (L-shaped, with orange wire connector) removed from a furnace, with HVAC wiring, blower motor, and service tools visible in the background.
- HVACPhotograph shows the interior of a pipe as viewed on a borescope camera screen, with visible rust/corrosion deposits and apparent cracking or separation at a pipe joint.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.