HVAC Service Invoice — No-charge service visit, no line items
- HVAC
On June 5, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 541 Autumn Bluff Drive, Ellisville, MO 63021.
- Record date
Available findings
- HVACCompleted work
Complete public upload archive
All 5 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 5.
Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.
Return to the property overviewOn June 5, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 541 Autumn Bluff Drive, Ellisville, MO 63021.
On October 12, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 541 Autumn Bluff Drive, Ellisville, MO 63021.
Heating season maintenance performed under the Residential Maintenance Plan.
Photograph shows an integrated furnace control board data plate with electrical ratings (24 VAC input, 60 Hz, XFMR SEC. current 450 MA, circ. blower output 14.5 FLA/25 LRA @ 120 VAC), wiring diagram for factory and field wiring, and timing specifications (prepurge 5 sec., interpurge 60 sec., IGN warmup 20 sec., retries 2, recycles 10, auto restart 60 min.).
Photograph shows a handheld digital thermometer (model SPK2) displaying a reading of 70.9°F, resting on a gray speckled surface.
the background reveals a circuit board and multi-colored wiring harnesses
Photograph shows a yellow digital thermometer (SPK2) reading 112°F placed across black and red conduit runs atop silver foil-faced Class 1 duct insulation (SF 686, rated to 200°F).
Photograph shows the interior of an open gas furnace panel with a manufacturer data/specification label visible, displaying vent pipe sizing, gas pressure specs, NOx emission limit of 40 ng/J, AHRI Certified and ETL (Intertek) listings, along with associated wiring.
Photograph shows a UEI EM152 digital manometer displaying a reading of -3.52 inH2O, being used to measure static pressure near HVAC equipment.
Photograph shows a Fasco blower motor (No. 71920333, Type U92B1) with a spec label reading 33-110V, 1.0A, 60-180 Hz, 1500-4700 RPM, Thermally Protected, Sealed Ball Bearing, Class B, installed in an HVAC unit with multicolor wiring visible in the background.
Photograph shows a USi EM152 digital manometer clipped to an HVAC unit frame displaying a negative static pressure reading of -1.70 inH2O, with visible blower motor, wiring, and circuit board components in the background.
Photograph shows a UEI EM152 digital manometer displaying a reading of -190 inH2O, with probes inserted into what appears to be an HVAC unit (furnace or air handler).
Photograph shows a metallic mesh humidifier water panel (evaporator pad) being held up, with visible mineral/scale buildup coating the expanded metal mesh surface.
Photograph shows a hand holding a metal insulation fastener pin with a flat circular metal flange and white plastic collar, with a tool tip visible at top of frame; background appears to be fabric clothing.
On May 27, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 541 Autumn Bluff Drive, Ellisville, MO 63021.
Supplied and installed a 4-ton American Standard 17 SEER2 two-stage air conditioner, 100,000 BTU variable-speed gas furnace, 4-ton evaporator coil, Sensi Wi-Fi thermostat, PVC condensate piping, pads, disconnect, and an Arzel zoning board and dampers.
Photograph shows a high-efficiency condensing gas furnace installed in a basement mechanical room, with dual white PVC flue and combustion-air intake pipes routed through the ceiling, sheet metal supply ductwork above, and a flexible gas line connection at the unit.
Photograph shows a high-efficiency gas furnace (tall gray cabinet) with white PVC intake and exhaust flue pipes routed overhead, installed in an unfinished basement mechanical room alongside sheet metal supply ductwork.
Photograph shows a high-efficiency condensing gas furnace with white PVC intake and exhaust flue pipes routed overhead, paired with a large air handler/coil cabinet, all installed in an unfinished basement mechanical room.
Photograph shows a gray outdoor air conditioning condenser unit mounted on a flat pad adjacent to a house with white vinyl siding, with refrigerant lines, electrical conduit, and a wall-mounted disconnect box visible.
Photograph shows an unfinished basement mechanical area with large galvanized sheet-metal ductwork and round elbow transitions at the ceiling, a gray electrical enclosure and disconnect box mounted on a plywood-framed wall, flexible metal conduit and wiring runs overhead, and what appears to be a filter or access panel with mesh screening on the lower portion of the framed enclosure.
a yellow service reminder sticker is affixed to the plenum, and a water heater is partially visible at upper right
On April 30, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 541 Autumn Bluff Drive, Ellisville, MO 63021.
Performed cooling season maintenance under the residential maintenance plan.
Photograph shows a heavily corroded and debris-covered dual-run capacitor inside an HVAC condenser unit, with multiple wire terminals connected at the top and significant rust and dirt accumulation on the capacitor body and terminal area.
On January 21, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 541 Autumn Bluff Drive, Ellisville, MO 63021.
Seasonal heating maintenance performed.
Photograph shows a forced air furnace manufacturer data plate with model TUH2C100A9V4VAB, serial 10314JFK7G, date of manufacture 8/2010, rated at 100,000 BTU/HR input and 65,000 BTU/HR output.
Photograph shows a borescope camera display screen capturing the interior of a metal component — two curved surfaces meeting at a seam with visible rust-colored staining and dark corrosion concentrated at the junction; screen displays a temperature reading of 122°F.
Photograph shows a borescope camera display capturing a close-up of a metal seam with visible rust, corrosion, and a crack or separation along the joint; probe temperature reads 120°F.
Photograph shows the interior of a furnace with the access panel removed, revealing multiple heat exchanger burner ports/cells, multi-colored wiring (yellow, green, black, white), flexible armored conduit, and a screwdriver resting on top of the unit cabinet.
Photograph shows a borescope screen displaying the interior of an HVAC component with a diagonal crack or debris streak visible on a curved white/gray surface, alongside a circular port opening; ambient temperature reads 118°F.
Photograph shows the interior of a furnace with the access panel removed, revealing significant rust and corrosion staining on the heat exchanger/burner area, along with the gas valve control (with ON/OFF and HI/LO markings), flexible metal conduit, and multi-colored wiring harness.
Photograph shows the interior of a furnace cabinet with a hot surface igniter (white ceramic rod), a transformer, flexible metallic armored conduit, multi-color wiring harness, and a gas supply pipe running diagonally across the cabinet floor.
Photograph shows a borescope camera display capturing an internal view of what appears to be a heat exchanger, with visible rust and brown/orange corrosion concentrated at the seam/junction between two curved metal surfaces; ambient temperature reads 120°F.
Photograph shows a borescope camera screen displaying the interior of a corrugated duct, flue, or heat exchanger passage at 118°F, with visible debris or particulate matter on the bottom of the passage; HVAC equipment components are visible in the background.
Photograph shows a pipe inspection camera monitor displaying the interior of a pipe with visible rust/orange staining on the pipe walls, moisture droplets, and a pipe joint or fitting centered in the frame.
Photograph shows the LCD screen of a pipe inspection borescope camera displaying the interior of a pipe with a visible longitudinal crack or joint separation accompanied by reddish-brown rust and corrosion staining along the seam; probe temperature reads 118°F and device timestamp reads 01-19-2026.
Photograph shows a sewer camera monitor displaying the interior of a pipe with a visible crack or break and orange/rust-colored staining radiating from a central dark void, indicating a structural defect in the pipe wall; a distance reading of approximately 192ft and a date stamp of 01-14-2026 are visible on the monitor screen.
Photograph shows the interior of a pipe or vessel wall captured on a borescope screen, displaying heavy rust/corrosion staining, a prominent longitudinal crack or seam with dark rust streaking, and a recorded ambient temperature of 116°F.
Photograph shows a technician holding a ceramic hot surface igniter (L-shaped, with orange wire connector) removed from a furnace, with HVAC wiring, blower motor, and service tools visible in the background.
Photograph shows the interior of a pipe as viewed on a borescope camera screen, with visible rust/corrosion deposits and apparent cracking or separation at a pipe joint.
View 541 Autumn Bluff Drive, Ellisville, MO 63021 on Fresh House