Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 2 documented records
Fresh House Property Summary
Highlights selected from 2 documented records for this property.
- HVAC · AC condenser coils cleaned as part of maintenance visit · Sep 2026
- HVAC · Refrigerant charge added and leak stop applied to AC · Sep 2026
- HVAC · AC maintenance plan purchased for ongoing service visits · Sep 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 5411 Oakvilla Manor Drive, St. Louis, MO 63129. The amount summary includes $883.50 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Maintenance Plan — AC maintenance plan
- HVAC
Built from Housecall Pro data
- $365HVACProvided a maintenance plan and performed AC maintenance.
- HVACPhotograph shows an outdoor air conditioning condenser unit with a manufacturer data plate reading Model No. 4AC13L48P-7A, Serial No. 1914K46780, containing HFC-410A refrigerant with a factory charge of 7 lbs 12 oz, assembled in Mexico, rated 208/230V single-phase.
- HVACPhotograph shows an outdoor HVAC condenser unit with data plate reading Model 4AC13L48P-7A, Serial 1914K46780, containing HFC-410A refrigerant, factory charge 7 lbs 12 oz, nominal voltage 208/230V, assembled in West Columbia, SC.
- HVACPhotograph shows Fieldpiece app live refrigerant measurements for R-410A system: suction pressure 110.8 psig, suction temperature 54.3°F, vapor saturation 36.5°F, actual superheat 17.8°F; liquid pressure 336.6 psig, liquid temperature 102.0°F, liquid saturation 103.9°F, actual subcooling 1.9°F, discharge pressure 336.6 psig.
- HVACPhotograph shows Fieldpiece app refrigerant measurements for R-410A system: suction pressure 111.3 psig, liquid pressure 337.3 psig, actual superheat 17.1°F, actual subcooling 1.6°F, and delta P -226.0 psig.
- HVACPhotograph shows an outdoor HVAC condenser unit with the top shroud removed, revealing condenser coil fins severely clogged with dirt, dust, and fibrous debris across all visible surfaces; tools are present on the ground nearby.
- HVACPhotograph shows an outdoor air conditioning condenser unit with louvered side panels and corrugated aluminum condenser fins; a yellow hand tool is visible on the ground at the base, and leaf debris is present around the unit.
- HVACPhotograph shows an outdoor HVAC condenser unit with its outer cabinet panels absent, exposing condenser coil fins that are heavily packed with dirt, dust, lint, and organic debris across all visible surfaces; the unit sits on a concrete pad against a concrete wall with overgrown vegetation around the base.
- HVACPhotograph shows an outdoor HVAC condenser unit with condenser coils and fins severely clogged with thick accumulations of dirt, dust, and debris across the lower and front panels, significantly restricting airflow; refrigerant lines and electrical conduit are visible at the base.
- HVACPhotograph shows an outdoor air conditioning condenser unit on a concrete pad with visibly dirty and debris-laden coil fins visible through the louvered grille; a technician's tool bag is present nearby on the grass.
- HVACPhotograph shows an outdoor HVAC condenser unit with aluminum fins severely fouled by compacted dirt, mud, and organic debris across all visible sides, with heaviest accumulation at the base; fin edges at the top show physical deterioration; a clamp meter is visible on the ground beside the unit.
- HVACPhotograph shows an outdoor air conditioning condenser unit with gray metal housing and louvered condenser coil fins; a partial warning label and QR code sticker are visible on the left panel; no visible damage to fins or cabinet in the photographed area.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Refrigerant Service — Refrigerant charge and leak stop added
- HVAC
Built from Housecall Pro data
- $519HVACAdded refrigerant charge (410, 3 lbs max) and applied refrigerant leak stop.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an outdoor condenser unit, displaying R410A refrigerant with low-side pressure of 128.5 psi (SH 10.3°F) and high-side pressure of 337.9 psi (SC 8.5°F).
- HVACPhotograph shows a CPS digital refrigerant scale displaying a reading of -1 lb 10.50 oz, with a red refrigerant hose and coiled cable visible on an outdoor stone surface.