Property records for 5411 Oakvilla Manor Drive, St. Louis, MO 63129

All 2 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 2.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Maintenance Plan — AC maintenance plan

  • HVAC

On September 9, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 5411 Oakvilla Manor Drive, St. Louis, MO 63129.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$365

    Provided a maintenance plan and performed AC maintenance.

  • HVACWork status not resolved

    Photograph shows an outdoor air conditioning condenser unit with a manufacturer data plate reading Model No. 4AC13L48P-7A, Serial No. 1914K46780, containing HFC-410A refrigerant with a factory charge of 7 lbs 12 oz, assembled in Mexico, rated 208/230V single-phase.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit with data plate reading Model 4AC13L48P-7A, Serial 1914K46780, containing HFC-410A refrigerant, factory charge 7 lbs 12 oz, nominal voltage 208/230V, assembled in West Columbia, SC.

  • HVACWork status not resolved

    Photograph shows Fieldpiece app live refrigerant measurements for R-410A system: suction pressure 110.8 psig, suction temperature 54.3°F, vapor saturation 36.5°F, actual superheat 17.8°F; liquid pressure 336.6 psig, liquid temperature 102.0°F, liquid saturation 103.9°F, actual subcooling 1.9°F, discharge pressure 336.6 psig.

  • HVACWork status not resolved

    Photograph shows Fieldpiece app refrigerant measurements for R-410A system: suction pressure 111.3 psig, liquid pressure 337.3 psig, actual superheat 17.1°F, actual subcooling 1.6°F, and delta P -226.0 psig.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit with the top shroud removed, revealing condenser coil fins severely clogged with dirt, dust, and fibrous debris across all visible surfaces; tools are present on the ground nearby.

  • HVACWork status not resolved

    Photograph shows an outdoor air conditioning condenser unit with louvered side panels and corrugated aluminum condenser fins; a yellow hand tool is visible on the ground at the base, and leaf debris is present around the unit.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit with its outer cabinet panels absent, exposing condenser coil fins that are heavily packed with dirt, dust, lint, and organic debris across all visible surfaces; the unit sits on a concrete pad against a concrete wall with overgrown vegetation around the base.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit with condenser coils and fins severely clogged with thick accumulations of dirt, dust, and debris across the lower and front panels, significantly restricting airflow; refrigerant lines and electrical conduit are visible at the base.

  • HVACWork status not resolved

    Photograph shows an outdoor air conditioning condenser unit on a concrete pad with visibly dirty and debris-laden coil fins visible through the louvered grille; a technician's tool bag is present nearby on the grass.

  • HVACWork status not resolved
  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit with aluminum fins severely fouled by compacted dirt, mud, and organic debris across all visible sides, with heaviest accumulation at the base; fin edges at the top show physical deterioration; a clamp meter is visible on the ground beside the unit.

  • HVACWork status not resolved

    Photograph shows an outdoor air conditioning condenser unit with gray metal housing and louvered condenser coil fins; a partial warning label and QR code sticker are visible on the left panel; no visible damage to fins or cabinet in the photographed area.

Record 2Public property record

HVAC Refrigerant Service — Refrigerant charge and leak stop added

  • HVAC

On September 30, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 5411 Oakvilla Manor Drive, St. Louis, MO 63129.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$519

    Added refrigerant charge (410, 3 lbs max) and applied refrigerant leak stop.

  • HVACWork status not resolved

    Photograph shows a Testo 557 digital manifold gauge connected to an outdoor condenser unit, displaying R410A refrigerant with low-side pressure of 128.5 psi (SH 10.3°F) and high-side pressure of 337.9 psi (SC 8.5°F).

  • HVACWork status not resolved

    Photograph shows a CPS digital refrigerant scale displaying a reading of -1 lb 10.50 oz, with a red refrigerant hose and coiled cable visible on an outdoor stone surface.