5513 Reineke Court
Across 4 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 4 documented records
Fresh House Property Summary
Highlights selected from 4 documented records for this property.
- HVAC · AC dual run capacitor replaced during overtime maintenance visit · Aug 2026
- HVAC · AC evaporator coil or full AC replacement proposed but not confirmed done · Aug 2026
- HVAC · Technician noted furnace has no accessible filter change point · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 4 documented records for 5513 Reineke Court, Jennings, MO 63136, dated from April 2026 through August 2026. The amount summary includes $849 in completed work across HVAC, $3,400 in estimates; appraisal values and permit-declared valuations are excluded.
HVAC Thermostat Installation — Non-programmable thermostat installed
- HVAC
Built from Housecall Pro data
- $349HVACPerformed a residential diagnostic service and installed a non-programmable thermostat.
- HVACPhotograph shows the back/interior of a disassembled thermostat (stamped '2044T') with visible wiring terminals, a cycle rate adjustment dial, mercury switch capsule, and resistors, placed on a cardboard box with mercury-disposal warning text.
- HVACMalfunctioning thermostat reported at 5513 Reineke Ct, flagged as high priority.
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Maintenance Service — Dual run capacitor supplied
- HVAC
Built from Housecall Pro data
- $500HVACOvertime trip fee, dual run capacitor supplied, and residential maintenance labor performed.
- HVACPhotograph shows the interior wiring compartment of an outdoor HVAC unit with the access panel removed, revealing a cylindrical run capacitor mounted to the interior wall, a multi-colored wiring bundle (yellow, red, brown, purple, blue, black, green wires), and a contactor or terminal block at the base of the compartment.
- HVACFieldpiece app air-side measurements show return dry bulb 87.0°F, supply dry bulb 72.6°F, Delta T 14.4°F, with return enthalpy 41.4 Btu/lbm and supply enthalpy 33.5 Btu/lbm; refrigerant-side data partially visible.
- HVACPhotograph shows Fieldpiece app refrigerant measurements for R-410A system: suction pressure 139.5 psig, suction temperature 72.8°F, vapor saturation 48.7°F, actual superheat 24.1°F; liquid pressure 317.8 psig, liquid temperature 90.8°F, liquid saturation 99.8°F, actual subcooling 9.0°F, discharge pressure 317.8 psig; air side dry bulb 73.5°F, target dry bulb 78.4°F.
- HVACthe system mode switch shows Heat/Off/Cool options and the fan switch shows Auto/On options
- HVACrefrigerant side partially visible with suction 139.9 psig and liquid 319.5 psig
- HVACFieldpiece app refrigerant-side diagnostics show R-410A system with suction pressure 128.8 psig, liquid pressure 305.1 psig, actual superheat 31.0°F (elevated), and actual subcooling 8.6°F; air-side dry bulb readings are not yet available.
- HVACPhotograph shows the open wiring compartment of a Goodman HVAC unit with multiple orange wire nuts joining a bundle of multi-colored low-voltage wires (red, green, blue, brown, white, yellow) to a large black conduit, along with a terminal block and additional wiring visible in the background.
- HVACHigh-priority work order: tenant reports thermostat not reaching set temperature and furnace does not appear to have an accessible filter change point; technician previously replaced thermostat battery approximately three months ago.
- HVACPhotograph shows a heavily soiled metal access panel on an HVAC air handler or furnace unit, sealed with Shurtape AF 100 foil tape that appears aged and partially peeling at the corners, with visible dirt and staining across the panel surface; flexible foil ductwork and a metal pipe are visible at the top.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Coil and AC Estimate — 2.5-ton Ameristar A/C + coil option
- HVAC
Options: New AC Coil and filter rack installation $3,400 · 2.5-Ton 13 SEER Ameristar Air Conditioner and Coil $7,205.50 (all expired)
Built from Housecall Pro data
- $3,400HVACEstimate for two options: a new AC evaporator coil with filter rack installation, or a 2.5-ton 13 SEER Ameristar air conditioner with new coil, both marked expired.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge HVAC service visit
- HVAC
Built from Housecall Pro data
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.