Record 1Public property record

HVAC Thermostat Installation — Non-programmable thermostat installed

  • HVAC

On April 20, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 5513 Reineke Court, Jennings, MO 63136.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$349

    Performed a residential diagnostic service and installed a non-programmable thermostat.

  • HVACWork status not resolved

    Photograph shows the back/interior of a disassembled thermostat (stamped '2044T') with visible wiring terminals, a cycle rate adjustment dial, mercury switch capsule, and resistors, placed on a cardboard box with mercury-disposal warning text.

  • HVACWork status not resolved

    Malfunctioning thermostat reported at 5513 Reineke Ct, flagged as high priority.

  • HVACWork status not resolved
Record 2Public property record

HVAC Maintenance Service — Dual run capacitor supplied

  • HVAC

On August 13, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 5513 Reineke Court, Jennings, MO 63136.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$500

    Overtime trip fee, dual run capacitor supplied, and residential maintenance labor performed.

  • HVACWork status not resolved

    Photograph shows the interior wiring compartment of an outdoor HVAC unit with the access panel removed, revealing a cylindrical run capacitor mounted to the interior wall, a multi-colored wiring bundle (yellow, red, brown, purple, blue, black, green wires), and a contactor or terminal block at the base of the compartment.

  • HVACWork status not resolved

    Fieldpiece app air-side measurements show return dry bulb 87.0°F, supply dry bulb 72.6°F, Delta T 14.4°F, with return enthalpy 41.4 Btu/lbm and supply enthalpy 33.5 Btu/lbm; refrigerant-side data partially visible.

  • HVACWork status not resolved

    Photograph shows Fieldpiece app refrigerant measurements for R-410A system: suction pressure 139.5 psig, suction temperature 72.8°F, vapor saturation 48.7°F, actual superheat 24.1°F; liquid pressure 317.8 psig, liquid temperature 90.8°F, liquid saturation 99.8°F, actual subcooling 9.0°F, discharge pressure 317.8 psig; air side dry bulb 73.5°F, target dry bulb 78.4°F.

  • HVACWork status not resolved

    the system mode switch shows Heat/Off/Cool options and the fan switch shows Auto/On options

  • HVACWork status not resolved

    refrigerant side partially visible with suction 139.9 psig and liquid 319.5 psig

  • HVACWork status not resolved

    Fieldpiece app refrigerant-side diagnostics show R-410A system with suction pressure 128.8 psig, liquid pressure 305.1 psig, actual superheat 31.0°F (elevated), and actual subcooling 8.6°F; air-side dry bulb readings are not yet available.

  • HVACWork status not resolved

    Photograph shows the open wiring compartment of a Goodman HVAC unit with multiple orange wire nuts joining a bundle of multi-colored low-voltage wires (red, green, blue, brown, white, yellow) to a large black conduit, along with a terminal block and additional wiring visible in the background.

  • HVACWork status not resolved

    High-priority work order: tenant reports thermostat not reaching set temperature and furnace does not appear to have an accessible filter change point; technician previously replaced thermostat battery approximately three months ago.

  • HVACWork status not resolved

    Photograph shows a heavily soiled metal access panel on an HVAC air handler or furnace unit, sealed with Shurtape AF 100 foil tape that appears aged and partially peeling at the corners, with visible dirt and staining across the panel surface; flexible foil ductwork and a metal pipe are visible at the top.

  • HVACWork status not resolved
Record 3Public property record

HVAC Coil and AC Estimate — 2.5-ton Ameristar A/C + coil option

  • HVAC

On August 13, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 5513 Reineke Court, Jennings, MO 63136.

Record date

Available findings

  • HVACEstimate or proposed work$3,400

    Estimate for two options: a new AC evaporator coil with filter rack installation, or a 2.5-ton 13 SEER Ameristar air conditioner with new coil, both marked expired.

Record 4Public property record

HVAC Service Invoice — No-charge HVAC service visit

  • HVAC

On August 14, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 5513 Reineke Court, Jennings, MO 63136.

Record date

Available findings

  • HVACCompleted work

View 5513 Reineke Court, Jennings, MO 63136 on Fresh House