HVACCompleted work$500
Overtime trip fee, dual run capacitor supplied, and residential maintenance labor performed.
HVACWork status not resolved
Photograph shows the interior wiring compartment of an outdoor HVAC unit with the access panel removed, revealing a cylindrical run capacitor mounted to the interior wall, a multi-colored wiring bundle (yellow, red, brown, purple, blue, black, green wires), and a contactor or terminal block at the base of the compartment.
HVACWork status not resolved
Fieldpiece app air-side measurements show return dry bulb 87.0°F, supply dry bulb 72.6°F, Delta T 14.4°F, with return enthalpy 41.4 Btu/lbm and supply enthalpy 33.5 Btu/lbm; refrigerant-side data partially visible.
HVACWork status not resolved
Photograph shows Fieldpiece app refrigerant measurements for R-410A system: suction pressure 139.5 psig, suction temperature 72.8°F, vapor saturation 48.7°F, actual superheat 24.1°F; liquid pressure 317.8 psig, liquid temperature 90.8°F, liquid saturation 99.8°F, actual subcooling 9.0°F, discharge pressure 317.8 psig; air side dry bulb 73.5°F, target dry bulb 78.4°F.
HVACWork status not resolved
the system mode switch shows Heat/Off/Cool options and the fan switch shows Auto/On options
HVACWork status not resolved
refrigerant side partially visible with suction 139.9 psig and liquid 319.5 psig
HVACWork status not resolved
Fieldpiece app refrigerant-side diagnostics show R-410A system with suction pressure 128.8 psig, liquid pressure 305.1 psig, actual superheat 31.0°F (elevated), and actual subcooling 8.6°F; air-side dry bulb readings are not yet available.
HVACWork status not resolved
Photograph shows the open wiring compartment of a Goodman HVAC unit with multiple orange wire nuts joining a bundle of multi-colored low-voltage wires (red, green, blue, brown, white, yellow) to a large black conduit, along with a terminal block and additional wiring visible in the background.
HVACWork status not resolved
High-priority work order: tenant reports thermostat not reaching set temperature and furnace does not appear to have an accessible filter change point; technician previously replaced thermostat battery approximately three months ago.
HVACWork status not resolved
Photograph shows a heavily soiled metal access panel on an HVAC air handler or furnace unit, sealed with Shurtape AF 100 foil tape that appears aged and partially peeling at the corners, with visible dirt and staining across the panel surface; flexible foil ductwork and a metal pipe are visible at the top.
HVACWork status not resolved