Hi, I'm 561 Prentice Drive. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
← MAPSOURCE-BACKED RECORDS
561 Prentice Drive
St. Peters, MO 6337638.7930°N, 90.6788°W
1Event
Contributed by:1 contributor

Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- HVAC · Heating and cooling system from 2022 is functioning correctly · 2026
- Foundation · Multiple cracks in basement walls need sealing or repair · 2026
- Roof · Roof is about 20 years old with significant wear · 2026
- Plumbing · Water heater inlet valve heavily rusted and needs replacement · 2026
- Windows · Two windows have broken seals and need replacement · 2026
Ask this homePowered by Fresh House property intelligence®
ASK ME ABOUT
RECORD SUMMARY
1 documented event
Contributed by: 1 contributor
First documented event: Jun 2026
Latest documented event: Jun 2026
First added to Fresh House: Jun 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
This page contains 1 documented record for 561 Prentice Drive, St. Peters, MO 63376, dated in June 2026.
Home Inspection
Home Inspection Document
Inspected Jun 24, 2026Uploaded Jun 29, 20262 files
Documented from uploaded report
Property Professional Uploaded
By
Greensmith Home Inspection llcdocumented Electrical, Foundation, HVAC, and 5 other topics at 561 Prentice Drive, St. Peters, MO 63376.
Scope
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Windows
Contributor
worked on or inspected it- Home InspectionWhole-home inspection of 561 Prentice Drive, St Peters, MO 63376 identified deficiencies in roofing, basement foundation walls, plumbing, and windows; HVAC and electrical systems were found satisfactory.
- PestWood Destroying Insect inspection of SFR/Attached Garage at 561 Prentice Drive found no visible evidence of wood destroying insects; no action or treatment recommended.
- ElectricalSiemens service panel (100 amps, underground service) with breaker overcurrent protection is satisfactory; smoke detectors tested satisfactory and no defects noted at outlets.
- FoundationCommon cracks are present in the interior and exterior of the basement concrete walls; three interior cracks appear large enough for epoxy injections while the others are smaller and can be sealed with urethane caulk.
- HVACGoodman central split system (manufactured 2022), gas forced-air furnace and 3-ton electric condenser, is functioning correctly with all components satisfactory.
- PlumbingBradford White gas water heater (manufactured 2017, 40 gal) is functioning properly but the cold water inlet valve is excessively rusted and needs replacement; master bathroom tub faucet finish has corroded and needs refinishing.
- RoofArchitectural shingle roof is estimated to be 20 years old and shows significant signs of wear; all other roofing components (ventilation, flashings, chimney, gutters, soffit/fascia) are satisfactory.
- WindowsTwo windows have broken seals; the window above the bathtub in the master bathroom and the far left window of the far left second-floor bedroom; one is particularly difficult to open and both need to be replaced.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.
PROPERTY COVERAGE
Home Inspection
✓ documentedRoof
✓ documentedPlumbing
✓ documentedFoundation
✓ documentedElectrical
✓ documentedHVAC
✓ documentedPest
✓ documentedWindows
✓ documentedSewer
undocumentedMold
undocumentedRadon
undocumentedAppraisals
undocumented