- HVAC · Air handler, heat kit, and AC system replaced with new line set · Mar 2024
- HVAC · Air handler and AC system replaced again with heat kit · May 2025$7k
- HVAC · New American Standard air conditioner and evaporator coil installed · Aug 2026
- Plumbing · Water heater installed by plumber · May 2024
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 12 documented records for 602 Forrester Drive, Ballwin, MO 63011, dated from March 2024 through May 2026. The amount summary includes $31,469.15 in completed work across HVAC and Plumbing; appraisal values and permit-declared valuations are excluded.
HVAC System Installation — Air handler, 10kW heat kit, new condenser
- HVAC
Built from Housecall Pro data
- $4,300HVACInstalled air handler, 10kW electric heat kit and new condenser, ran new line set, evacuated the system and charged with 410a.
Documented warranty1 year / 5 yearFrom invoiceView details
What this warranty covers
- parts
· source
“1 year parts and warranty”
- manufacturer parts
· source
“5 year manufacturer parts warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Plumbing Water Heater Installation — Customer supplied water heater
- Plumbing
Built from Housecall Pro data
- $650PlumbingInstalled a customer supplied water heater.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Work — 35/5 dual run capacitor and R-22 supplied
- HVAC
Built from Housecall Pro data
- $429HVACDiagnostic visit performed with a 35/5 dual run capacitor supplied and R-22 refrigerant provided.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Thermostat Replacement — Thermostat replaced, units checked
- HVAC
Built from Housecall Pro data
- $445HVACReplaced thermostat and checked units.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Refrigerant Service — 410a refrigerant supplied
- HVAC
Built from Housecall Pro data
- $320HVACSupplied 410a refrigerant.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC System Installation — Air handler, 15 kw heat kit, 2.5-ton AC
- HVAC
Built from Housecall Pro data
- $6,960HVACInstalled an air handler, 15 kw heat kit, and 2.5 ton AC system; a dual run capacitor was supplied, and a water heater expansion tank and relief valve line was included.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Coil Replacement — AC coil replaced
- HVAC
Built from Housecall Pro data
- $1,465HVACReplaced non warranty AC coil.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic Service — Diagnostic visit with flex gas connector
- HVAC
Built from Housecall Pro data
- $244HVACDiagnostic trip, residential labor performed, and a flex gas connector supplied.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Installation — Lennox A/C and air handler installed
- HVAC
Built from Housecall Pro data
- $7,320HVACInstalled Lennox air conditioner and air handler.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Repair Invoice — A/C contactor replaced, R22 charge added
- HVAC
Built from Housecall Pro data
- $815HVACReplaced air conditioner contactor, rewired disconnect whip, and added R22 refrigerant charge (2 lb max).
- HVACPhotograph shows the interior of an HVAC unit with a control circuit board (part no. 1194-83-2501A) featuring labeled low-voltage thermostat terminals (COM, SEC, W, G, Y, R, C), fuse holder (F1), a purple jumper labeled 'E', resistors, and multiple colored wiring harnesses connected throughout.
- HVACPhotograph shows a thermostat wall plate with cover removed, exposing two terminal blocks with multiple low-voltage wires (white, red, green, yellow, blue) connected to labeled terminals including W2, B, G, W1, C, L, O, Y1, and Rc; wires appear loosely bundled.
- HVACPhotograph shows the interior compartment of an HVAC unit with heavy accumulation of dried leaves and debris on the floor, a heavily corroded capacitor, aged and dirty multi-conductor wiring with red wire nuts, and peeling/flaking paint on the metal enclosure walls.
- HVACPhotograph shows multiple electrical wire splices joined with wire nuts and hanging freely from a wooden floor joist, with no enclosing junction box visible.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Estimate Visit — Estimate visit, no charge
- HVAC
Built from Housecall Pro data
- HVACAn estimate visit was performed at the property at no charge.
- HVACPhotograph shows the interior data plate of a Rheem forced-air natural gas furnace, model R801TA100521MSA, serial W402023994, manufactured October 2020, rated at 96,000 BTU/hr maximum input, equipped for natural gas.
- HVACPhotograph shows an outdoor HVAC condenser unit with condenser coil fins heavily coated in dirt, dust, and organic debris; refrigerant lines and tubing are visible with surface oxidation/patina, and the base pan contains accumulated leaves, twigs, and debris.
- HVACPhotograph shows a close-up of a white-painted cast iron radiator with multiple vertical fins/sections; a partial manufacturer label is visible between the fins, and a teal-colored pipe or fitting is visible at the upper right; paint shows age and surface wear.
- HVACPhotograph shows a basement furnace/air handler unit with heavy dark staining and sooting visible on the sheet metal cabinet and ductwork; a control or ignition component is mounted on the unit's side panel.
- HVACPhotograph shows an outdoor HVAC condenser unit with the access panel removed, revealing severely fouled condenser coil fins packed with dirt and debris across the entire coil face, significant rust and corrosion on the base pan and lower components, standing water at the unit base, and partially deteriorated refrigerant line insulation.
- HVACTTB742A100A0, Serial No. C44201897, manufactured 10/88, factory charged with Refrigerant 22 (6 lbs. 8 oz.) unit exterior appears weathered
- HVACdebris (leaves and dirt) is visible inside the condenser cabinet
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Installation — 4-ton 16 SEER2 A/C + evaporator coil
- HVAC
Built from Housecall Pro data
- $8,521HVACInstalled an American Standard 4-ton 16 SEER2 R-454B air conditioner with a matching 4/5 ton evaporator coil, condenser pad, and 60-amp disconnect, with journeyman and apprentice labor.
- HVACPhotograph shows a vertical metal air handler unit installed in a basement, with metallic duct tape sealing section joints and a foil-faced insulated plenum connecting to overhead ductwork.
- HVACPhotograph shows an outdoor air conditioning condenser unit (appearing to be American Standard brand) mounted on a concrete pad against a brick exterior wall, with an electrical disconnect box mounted on the wall to the right and a satellite dish above; shrubs are growing in close proximity to the unit.
- HVACPhotograph shows a large vertical sheet-metal air handler unit in a basement, with copper refrigerant lines and a small control/switch box mounted on the front panel; a white water heater is visible immediately behind it to the left.
- HVACPhotograph shows a basement mechanical room with a gas furnace, an air handler/coil unit, and extensive sheet metal ductwork overhead; copper refrigerant lines run from the air handler upward, and a condensate drain line is visible.
- HVACPhotograph shows an open HVAC air handler cabinet with a heavily corroded evaporator coil, severely rusted coil frame and drain pan, deteriorated foil-faced insulation on the cabinet interior, and copper refrigerant lines exhibiting surface oxidation; indicating significant long-term moisture exposure and advanced deterioration.
- HVACunit cabinet and fin coils appear intact with no visible damage
- HVACPhotograph shows an outdoor air conditioning condenser unit mounted on a concrete pad against the rear brick exterior wall of a residential property, with refrigerant line set entering the wall above, surrounded by lawn and shrubs.
- HVACPhotograph shows an older vertical furnace/air handler unit with sheet metal ductwork, a humidifier component on top, a filter access panel at the bottom, and a wall-mounted humidity control; visible discoloration and staining on the concrete floor beneath and around the unit.
- HVACPhotograph shows a boxed HVAC unit on a label reading Model Number 5A7A6048A1000A, Serial Number 262833RKKF, Made in USA, with a flammable/oxidizer hazard symbol; the cardboard box is secured with green strapping and shows minor top-corner damage.
- HVACPhotograph shows a large cardboard box on grass bearing a product label with Model Number 5PXCC007AS3HAA, Serial Number 26245K6ABG, assembled in USA, indicating an uninstalled HVAC unit.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.