Record 1Public property record

HVAC System Installation — Air handler, 10kW heat kit, new condenser

  • HVAC

On March 10, 2024, JLM HEATING AND AIR CONDITIONING documented HVAC at 602 Forrester Drive, Ballwin, MO 63011.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$4,300

    Installed air handler, 10kW electric heat kit and new condenser, ran new line set, evacuated the system and charged with 410a.

Record 2Public property record

Plumbing Water Heater Installation — Customer supplied water heater

  • Plumbing

On May 4, 2024, JLM HEATING AND AIR CONDITIONING documented Plumbing at 602 Forrester Drive, Ballwin, MO 63011.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • PlumbingCompleted work$650

    Installed a customer supplied water heater.

Record 3Public property record

HVAC Work — 35/5 dual run capacitor and R-22 supplied

  • HVAC

On July 13, 2024, JLM HEATING AND AIR CONDITIONING documented HVAC at 602 Forrester Drive, Ballwin, MO 63011.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$429

    Diagnostic visit performed with a 35/5 dual run capacitor supplied and R-22 refrigerant provided.

Record 4Public property record

HVAC Thermostat Replacement — Thermostat replaced, units checked

  • HVAC

On September 3, 2024, JLM HEATING AND AIR CONDITIONING documented HVAC at 602 Forrester Drive, Ballwin, MO 63011.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$445

    Replaced thermostat and checked units.

Record 5Public property record

HVAC Refrigerant Service — 410a refrigerant supplied

  • HVAC

On April 10, 2025, JLM HEATING AND AIR CONDITIONING documented HVAC at 602 Forrester Drive, Ballwin, MO 63011.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$320

    Supplied 410a refrigerant.

Record 6Public property record

HVAC System Installation — Air handler, 15 kw heat kit, 2.5-ton AC

  • HVAC

On May 4, 2025, JLM HEATING AND AIR CONDITIONING documented HVAC at 602 Forrester Drive, Ballwin, MO 63011.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$6,960

    Installed an air handler, 15 kw heat kit, and 2.5 ton AC system; a dual run capacitor was supplied, and a water heater expansion tank and relief valve line was included.

Record 7Public property record

HVAC Coil Replacement — AC coil replaced

  • HVAC

On June 15, 2025, JLM HEATING AND AIR CONDITIONING documented HVAC at 602 Forrester Drive, Ballwin, MO 63011.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$1,465

    Replaced non warranty AC coil.

Record 8Public property record

HVAC Diagnostic Service — Diagnostic visit with flex gas connector

  • HVAC

On October 26, 2025, JLM HEATING AND AIR CONDITIONING documented HVAC at 602 Forrester Drive, Ballwin, MO 63011.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$244

    Diagnostic trip, residential labor performed, and a flex gas connector supplied.

Record 9Public property record

HVAC Installation — Lennox A/C and air handler installed

  • HVAC

On November 21, 2025, JLM HEATING AND AIR CONDITIONING documented HVAC at 602 Forrester Drive, Ballwin, MO 63011.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$7,320

    Installed Lennox air conditioner and air handler.

Record 10Public property record

HVAC Repair Invoice — A/C contactor replaced, R22 charge added

  • HVAC

On May 26, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 602 Forrester Drive, Ballwin, MO 63011.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$815

    Replaced air conditioner contactor, rewired disconnect whip, and added R22 refrigerant charge (2 lb max).

  • HVACWork status not resolved

    Photograph shows the interior of an HVAC unit with a control circuit board (part no. 1194-83-2501A) featuring labeled low-voltage thermostat terminals (COM, SEC, W, G, Y, R, C), fuse holder (F1), a purple jumper labeled 'E', resistors, and multiple colored wiring harnesses connected throughout.

  • HVACWork status not resolved

    Photograph shows a thermostat wall plate with cover removed, exposing two terminal blocks with multiple low-voltage wires (white, red, green, yellow, blue) connected to labeled terminals including W2, B, G, W1, C, L, O, Y1, and Rc; wires appear loosely bundled.

  • HVACWork status not resolved

    Photograph shows the interior compartment of an HVAC unit with heavy accumulation of dried leaves and debris on the floor, a heavily corroded capacitor, aged and dirty multi-conductor wiring with red wire nuts, and peeling/flaking paint on the metal enclosure walls.

  • HVACWork status not resolved

    Photograph shows multiple electrical wire splices joined with wire nuts and hanging freely from a wooden floor joist, with no enclosing junction box visible.

Record 11Public property record

HVAC Estimate Visit — Estimate visit, no charge

  • HVAC

On August 14, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 602 Forrester Drive, Ballwin, MO 63011.

Record date

Available findings

  • HVACCompleted work

    An estimate visit was performed at the property at no charge.

  • HVACWork status not resolved

    Photograph shows the interior data plate of a Rheem forced-air natural gas furnace, model R801TA100521MSA, serial W402023994, manufactured October 2020, rated at 96,000 BTU/hr maximum input, equipped for natural gas.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit with condenser coil fins heavily coated in dirt, dust, and organic debris; refrigerant lines and tubing are visible with surface oxidation/patina, and the base pan contains accumulated leaves, twigs, and debris.

  • HVACWork status not resolved

    Photograph shows a close-up of a white-painted cast iron radiator with multiple vertical fins/sections; a partial manufacturer label is visible between the fins, and a teal-colored pipe or fitting is visible at the upper right; paint shows age and surface wear.

  • HVACWork status not resolved

    Photograph shows a basement furnace/air handler unit with heavy dark staining and sooting visible on the sheet metal cabinet and ductwork; a control or ignition component is mounted on the unit's side panel.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit with the access panel removed, revealing severely fouled condenser coil fins packed with dirt and debris across the entire coil face, significant rust and corrosion on the base pan and lower components, standing water at the unit base, and partially deteriorated refrigerant line insulation.

  • HVACWork status not resolved

    TTB742A100A0, Serial No. C44201897, manufactured 10/88, factory charged with Refrigerant 22 (6 lbs. 8 oz.) unit exterior appears weathered

  • HVACWork status not resolved

    debris (leaves and dirt) is visible inside the condenser cabinet

Record 12Public property record

HVAC Installation — 4-ton 16 SEER2 A/C + evaporator coil

  • HVAC

On August 20, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 602 Forrester Drive, Ballwin, MO 63011.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$8,521

    Installed an American Standard 4-ton 16 SEER2 R-454B air conditioner with a matching 4/5 ton evaporator coil, condenser pad, and 60-amp disconnect, with journeyman and apprentice labor.

  • HVACWork status not resolved

    Photograph shows a vertical metal air handler unit installed in a basement, with metallic duct tape sealing section joints and a foil-faced insulated plenum connecting to overhead ductwork.

  • HVACWork status not resolved

    Photograph shows an outdoor air conditioning condenser unit (appearing to be American Standard brand) mounted on a concrete pad against a brick exterior wall, with an electrical disconnect box mounted on the wall to the right and a satellite dish above; shrubs are growing in close proximity to the unit.

  • HVACWork status not resolved

    Photograph shows a large vertical sheet-metal air handler unit in a basement, with copper refrigerant lines and a small control/switch box mounted on the front panel; a white water heater is visible immediately behind it to the left.

  • HVACWork status not resolved

    Photograph shows a basement mechanical room with a gas furnace, an air handler/coil unit, and extensive sheet metal ductwork overhead; copper refrigerant lines run from the air handler upward, and a condensate drain line is visible.

  • HVACWork status not resolved

    Photograph shows an open HVAC air handler cabinet with a heavily corroded evaporator coil, severely rusted coil frame and drain pan, deteriorated foil-faced insulation on the cabinet interior, and copper refrigerant lines exhibiting surface oxidation — indicating significant long-term moisture exposure and advanced deterioration.

  • HVACWork status not resolved

    unit cabinet and fin coils appear intact with no visible damage

  • HVACWork status not resolved

    Photograph shows an outdoor air conditioning condenser unit mounted on a concrete pad against the rear brick exterior wall of a residential property, with refrigerant line set entering the wall above, surrounded by lawn and shrubs.

  • HVACWork status not resolved

    Photograph shows an older vertical furnace/air handler unit with sheet metal ductwork, a humidifier component on top, a filter access panel at the bottom, and a wall-mounted humidity control; visible discoloration and staining on the concrete floor beneath and around the unit.

  • HVACWork status not resolved

    Photograph shows a boxed HVAC unit on a label reading Model Number 5A7A6048A1000A, Serial Number 262833RKKF, Made in USA, with a flammable/oxidizer hazard symbol; the cardboard box is secured with green strapping and shows minor top-corner damage.

  • HVACWork status not resolved

    Photograph shows a large cardboard box on grass bearing a product label with Model Number 5PXCC007AS3HAA, Serial Number 26245K6ABG, assembled in USA, indicating an uninstalled HVAC unit.

  • HVACWork status not resolved