Hi, I'm 616 Silver Maple Drive. I only speak from this property's source-backed records — 2 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
616 Silver Maple Drive
Across 2 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 2 documented records
Fresh House Property Summary
Highlights selected from 2 documented records for this property.
- HVAC · Air conditioner, evaporator coil, and furnace replaced with new thermostat · Jun 2026
- HVAC · Condenser fan motor and capacitor replaced at a prior service visit · Jun 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 616 Silver Maple Drive, Fenton, MO 63026, dated in June 2026. The amount summary includes $10,209.72 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Maintenance — Condenser fan motor and capacitor
- HVAC
Built from Housecall Pro data
- $699HVACPerformed a residential diagnostic service and provided a condenser fan motor and capacitor.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Installation — 3-ton A/C, coil and 80,000 BTU furnace
- HVAC
Built from Housecall Pro data
- $9,511HVACInstalled an American Standard 3-ton air conditioner, evaporator coil, 80,000 BTU gas furnace and Sensi Wi-Fi thermostat, with condenser pad, disconnect, flue pipe, filter rack and installation materials and labor.
- HVACPhotograph shows a Fieldpiece app Measurements screen during a refrigerant Recover task, displaying a net weight change of -2 lb (15.50 oz) and a gross tank weight of 25 lb.
- HVACPhotograph shows Fieldpiece app screen displaying live refrigerant-side measurements for an R-454B system: suction pressure 121.5 psig, liquid pressure 313.9 psig, actual superheat 12.8°F, actual subcooling 9.7°F, and discharge pressure 121.5 psig.
- HVAC15 oz. refrigerant charge fields at bottom are blank
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.