Fresh House Property Summary
Highlights selected from 2 documented records for this property.
- HVAC · Commercial HVAC service visit performed at the property · Aug 2026
- HVAC · Rooftop unit replacement or repair options were estimated but not confirmed · Aug 2026$10k
- HVAC · Estimate included Trane heat exchanger, R-22 refrigerant, and evaporator pan repair · Aug 2026
- HVAC · R-22 system refrigerant readings recorded; R-410A unit also tested on same visit · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 6255 Ronald Reagan Drive, Lake St. Louis, MO 63367, dated in August 2026. The amount summary includes $260 in completed work across HVAC, $10,460 in estimates; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Commercial trip fee and labor
- HVAC
Built from Housecall Pro data
- $260HVACCommercial trip fee and commercial labor were performed at the service address.
- HVACPhotograph shows the lower exterior of a package/rooftop HVAC unit with visible rust and corrosion along the base pan, an open rectangular drain slot in the base, a circular drain cap/plug, accumulated debris (leaves and dirt) at the unit's base, and an open access panel on the right side exposing internal refrigerant lines.
- HVACPhotograph shows HVAC refrigerant diagnostic app displaying R-410A system readings: suction pressure 144.0 psig / 59.4°F, vapor saturation 50.5°F, actual superheat 8.9°F; liquid pressure 369.3 psig / 103.5°F, liquid saturation 110.5°F, actual subcooling 7.0°F, discharge pressure 369.3 psig; air side dry bulb 62.0°F, target dry bulb 62.1°F.
- HVACFieldpiece app refrigerant-side measurements show R-22 system with suction pressure 66.6 psig, liquid pressure 327.6 psig, actual superheat 29.6°F, actual subcooling 39.1°F, and air-side dry bulb 64.9°F.
- HVACPhotograph shows a cylindrical tank or pipe surface with extensive cracking and crazing of the outer coating, and heavy dark black spotting concentrated at the top seam/joint area, with additional scattered spotting across the surface.
- HVACPhotograph shows a Fluke 323 True RMS Clamp Meter displaying approximately 53 amps AC, being used to measure current on electrical wiring near sheet-metal equipment.
- HVACFieldpiece app refrigerant side measurements show R-410A with suction pressure 140.2 psig, liquid pressure 309.4 psig, actual superheat 12.5°F, actual subcooling 9.6°F; air side diagnostics indicate supply dry bulb (63.0°F) is close to target dry bulb (63.1°F), indicating adequate evaporator performance.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Rooftop Unit Estimate — 5-ton Trane RTU replacement option
- HVAC
Options: Repair Items $10,460 · 5-ton Trane Replacement $15,440 · 5-tom Goodman $15,067 (all expired)
Built from Housecall Pro data
- $10,460HVACEstimate for three expired options: repair items including Trane heat exchanger, R-22 and evaporator pan; a 5-ton Trane RTU replacement; and a 5-ton Goodman RTU replacement, with crane, permit and smoke detector.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this property.