← MAP

6264 Water Tower Place Drive

St. Louis, MO 6312938.4506°N, 90.3078°W
3Events
Contributed by:1 contributor
$13kDocumented amounts
SOURCE-BACKED RECORDS

Across 3 records on this home

Completed work

Invoices and paid receipts

$13k

Estimated · not confirmed

Quotes, estimates, and other amounts not confirmed as performed

None documented yet

Property History Report

Negotiate this home like you've seen its receipts. You have.

Free right now · built from this home's 3 documented records

Fresh House Property Summary

Highlights selected from 3 documented records for this property.

  • HVAC
    HVAC · Air conditioner, furnace, and evaporator coil replaced with new Lennox system · Mar 2026
  • HVAC
    HVAC · New Wi-Fi thermostat installed with the HVAC replacement · Mar 2026
  • HVAC
    HVAC · HVAC system received heating and new-equipment maintenance visit · Sep 2026
Ask this homePowered by Fresh House property intelligence®
THE HOME

Hi, I'm 6264 Water Tower Place Drive. I only speak from this property's source-backed records — 3 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.

ASK ME ABOUT

RECORD SUMMARY

3 documented events
Contributed by: 1 contributor
First documented event: May 2026
Latest documented event: May 2026
First added to Fresh House: Nov 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 3 documented records for 6264 Water Tower Place Drive, St. Louis, MO 63129, dated in May 2026. The amount summary includes $13,225.92 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.

HVAC

HVAC Installation — 3-ton A/C + 80% AFUE furnace + coil

Document dated Mar 25, 2026Uploaded Nov 8, 20269 files
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 6264 Water Tower Place Drive, St. Louis, MO 63129.
Scope
  • HVAC
Outcome
Paid in full

Built from Housecall Pro data

Total documented value on this timeline entry: $13,226
  • HVACInstalled a 3-ton ML17KC2 two-stage air conditioner, 3-ton evaporator coil, EL280UH090E36BK 80% AFUE gas furnace, and Lennox M30 Wi-Fi thermostat, with flue pipe, condenser pad, 30-amp disconnect, and install materials.
    $13,226
  • HVACPhotograph shows an outdoor air conditioning condenser unit mounted on a ground-level pad against the exterior foundation wall, with a wall-mounted disconnect box and refrigerant/electrical lines running from the unit to the structure.
  • HVACPhotograph shows a Lennox Elite Series gas furnace with sheet metal ductwork, round flue exhaust vent, copper refrigerant line, and black gas supply piping in a basement utility area.
Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC
Attached photo 4HVAC
+4

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Service Invoice — No-charge service visit, no line items

Document dated May 4, 2026Uploaded Nov 8, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 6264 Water Tower Place Drive, St. Louis, MO 63129.
Scope
  • HVAC
Contributor
worked on or inspected it

Built from Housecall Pro data

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Heating Maintenance — Heating maintenance performed

Document dated Sep 5, 2026Uploaded Nov 8, 20264 files
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 6264 Water Tower Place Drive, St. Louis, MO 63129.
Scope
  • HVAC

Built from Housecall Pro data

  • HVACHeating maintenance and new equipment maintenance performed.
  • HVACDigital manifold gauge app shows R-410A system readings: suction pressure 105.2 psig, liquid pressure 282.6 psig, actual superheat 22.6°F, actual subcooling 13.3°F, and Delta P of -177.4 psig.
  • HVACRefrigerant diagnostic app shows R-410A system with suction pressure 105.1 psig, liquid pressure 272.1 psig, actual superheat 22.7°F, and actual subcooling 11.5°F.
Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this home.

PROPERTY COVERAGE

HVAC
✓ documented
Home Inspection
undocumented
Roof
undocumented
Plumbing
undocumented
Sewer
undocumented
Foundation
undocumented
Mold
undocumented
Electrical
undocumented
Pest
undocumented
Radon
undocumented
Appraisals
undocumented
Windows
undocumented

Nearby homes with documented history