Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- HVAC · HVAC diagnostic service performed with St. Louis County mechanical permit · Aug 2026
- HVAC · Gas line replaced and union added at the furnace · Aug 2026
- HVAC · Duct joints sealed with UL-listed tape at the air handler · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 6371 Treeridge Trail, St. Louis, MO 63129. The amount summary includes $1,074 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Repair Invoice — Gas line replaced, union added, joints sealed
- HVAC
Built from Housecall Pro data
- $1,074HVACPerformed residential diagnostic service, pulled St. Louis County mechanical permit, sealed all joints with UL listed tape, replaced gas line and added union, and supplied 2 refrigerant locking caps.
- HVACPhotograph shows a dark-colored furnace/air handler unit in a basement mechanical room with a sheet metal supply plenum connecting to overhead rectangular ductwork, a round blue zone damper or control device mounted to the right, and galvanized round duct runs visible in the background.
- HVACPhotograph shows the interior of an HVAC unit with multiple exposed wires (red, yellow, orange, white, black), a conduit wrapped in black foam insulation tape entering through a knockout fitting, and white sealant visible around connections.
- HVACPhotograph shows a round galvanized metal flue/exhaust pipe rising from the top panel of a gray HVAC unit, secured by a square bolt-fastened flange plate; a visible gap exists between the flange and the unit's top panel, and the pipe surface shows oxidation and residual tape or sealant near the upper section.
- HVACPhotograph shows an HVAC air handler or furnace with a large round galvanized duct collar rising from the top of the cabinet; the base plate of the duct has a visible gap between it and the unit cabinet, and the duct tape sealing the collar connection is visibly damaged and peeling. A condensate drain line is visible on the right side of the unit. A yellow warning label on the left panel references a leak detection system and refrigerant safety group A2L.
- HVACPhotograph shows a square sheet metal plenum or supply transition box connected atop a dark air handler unit, with all seams sealed using Shurtape AF 099 UL 181A-P/181B-FX rated foil tape; a round flexible duct collar is visible to the right and additional round metal ductwork to the left.
- HVACPhotograph shows a galvanized sheet metal plenum or transition duct fastened with screws along its seam, adjacent to a dark-colored air handler cabinet, with a visible blower wheel assembly and bundled electrical wiring secured with a zip tie.
- HVACPhotograph shows the lower section of an outdoor air conditioning condensing unit with brass refrigerant service valves and Schrader ports visible; dead leaves, twigs, and debris have accumulated around the base of the unit; a refrigerant safety group A2L label and trilingual warning sticker are affixed to the unit cabinet.
- HVACPhotograph shows the manufacturer data plate on a Daikin outdoor air conditioning unit, model GLXS5BA3010AA, serial 2508038477, rated 208/230V single-phase, 60Hz, with R-32 refrigerant and AHRI certification.
- HVACa gas flex connector and black iron pipe are visible on the left side
- HVACPhotograph shows a multi-section galvanized metal flue vent stack rising vertically through floor framing in a basement space, connected to a black sheet-metal collar at the ceiling, with a branching duct elbow at the lower section; copper piping and electrical wiring are also visible in the background.
- HVACPhotograph shows the interior wiring compartment of an HVAC unit with multiple colored wires (orange, red, white, black, brown, yellow) joined by yellow and black twist-on wire nuts, and a small mounted component (possibly a pressure switch or relay) visible at the top of the enclosure.
- HVACPhotograph shows the lower section of an outdoor HVAC condenser unit with brass refrigerant service valves, red-capped Schrader valve ports on the refrigerant lines, and heavy accumulation of dead leaves, twigs, and debris inside the unit base.
- UnclassifiedPhotograph shows a close-up of a gray textured metal surface with a horizontal seam or joint running across the middle, two small fastener points visible along the seam, and scattered white debris or dust particles on the lower portion.
HVAC
HVAC
HVAC