Property records for 6809 Saint Olaf Drive, Berkeley, MO 63134
All 7 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 7.
Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.
HVAC Condenser and Coil Replacement — 2.5-ton R410A coil
HVAC
On April 24, 2025, ASSURED HEATING AND COOLING documented HVAC at 6809 Saint Olaf Drive, Berkeley, MO 63134.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$3,324
Work performed: Coil/Condenser 2.5 Ton R410A System (We propose to install the following equipment in above listed unit); Coil/Condensing Unit Install Description (This quote includes, fused disconnect, electrical whip and pad for condensing); Equipment Warranty; Payment/Terms; Terms and Conditions.
Record 2·Public property record
Plumbing Drain Cleaning — Outside drain cabled and cleaned
Plumbing
Drain Clean USA, LLC documented Plumbing at 6809 Saint Olaf Drive, Berkeley, MO 63134.
Available findings
Plumbing$300
Cabled outside after drain (D-S cable outside after drain); 30-day warranty; paid in full.
Record 3·Public property record
Document
Electrical
Foundation
HVAC
Home Inspection
Plumbing
Roof
Windows
On December 13, 2022, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 4 other topics at 6809 Saint Olaf Drive, Berkeley, MO 63134.
Record date
Available findings
Electrical
Tree limbs are pushing on overhead power lines; one living room outlet has no power and needs repair or replacement; ungrounded two-prong outlets are present throughout the home.
Foundation
Slab-on-grade foundation with concrete block material and wood frame wall structure observed in satisfactory condition with no structural deficiencies noted.
Home Inspection
Whole-home inspection of single-family property identified active roof leaks, HVAC ductwork issues, electrical deficiencies, and interior ceiling damage requiring repair before occupancy.
HVAC
HVAC flexible ductwork is twisted and does not heat or cool evenly per occupant; furnace filter is missing; AC compressor (International Comfort, Mfgd 2018) is functional but dirty and needs cleaning.
Plumbing
PVC supply pipes are satisfactory; Rheem 40-gallon electric water heater (Mfgd 2018) is functional with T&P relief valve present, but lacks a fuel disconnect.
Roof
Extensive damage to 3-tab shingled roof (estimated 15 years old) with tarpaper exposed, tattered roof tarp in place, active roof leaks present, and gutters clogged with leaves and debris.
Windows
Exterior windows (wood, vinyl, aluminum) and interior windows (double hung, fixed) are in satisfactory condition with no defects observed.
Record 4·Public property record
HVAC Diagnostic Service — Unsealed flue vent letting outdoor air
HVAC
On January 20, 2025, Arch Air Services documented HVAC at 6809 Saint Olaf Drive, Berkeley, MO 63134.
Record date
Available findings
HVAC$188
Performed diagnostic and service call; sealed penetration and old flue vent to prevent outdoor air from entering the return air space, which was dropping heat delivery temperature — system running normally, new system and ductwork recommended.
Record 5·Public property record
HVAC Ductwork Installation — Supply duct modified
HVAC
Arch Air Services documented HVAC at 6809 Saint Olaf Drive, Berkeley, MO 63134.
Available findings
HVAC$1,920
Installed ductwork by modifying the supply air duct system, closing off old unused return air duct, opening soffit in kitchen to run a larger duct, connecting a 14" insulated flex duct from the soffit to the existing supply trunk in the attic, and removing old 6" supply flex duct with hole patching.
Record 6·Public property record
HVAC Diagnostic Service — System undercharged; possible leak
HVAC
On August 28, 2024, Arch Air Services documented HVAC at 6809 Saint Olaf Drive, Berkeley, MO 63134.
Record date
Available findings
HVAC$303
Diagnostic and service call performed; system found undercharged, 1 pound of 410A refrigerant added and balanced, possible leak identified in indoor coil and outdoor service valve, cap placed on outdoor valve.
Record 7·Public property record
Document
Sewer
This record documents Sewer at 6809 Saint Olaf Drive, Berkeley, MO 63134.
Record description
This house had multiple sewer issues when owning it. It was recommended to service it at least once per year