6809 Saint Olaf Drive
Across 7 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes & estimates, not confirmed as performed
Status not stated
Amount documented; completion not confirmed

Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 7 documented records
Fresh House Property Summary
Highlights selected from 7 documented records for this property.
- HVAC · Ductwork overhauled with new supply air routing and connections · 2026
- Electrical · Ungrounded outlets and tree limbs pressing on power lines found · 2022
- HVAC · Refrigerant leak suspected in indoor coil and outdoor valve · 2024
- Roof · Active roof leaks and extensive shingle damage found · 2022
- Appraisals · Appraisal recorded at $142,000 · 2024
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 7 documented records for 6809 Saint Olaf Drive, Berkeley, MO 63134, dated from December 2022 through January 2025. The amount summary includes $2,711 with completion status not stated; appraisal values and permit-declared valuations are excluded.
Plumbing Drain Cleaning — Outside drain cabled and cleaned
Drain Clean USA, LLC documented Plumbing at 6809 Saint Olaf Drive, Berkeley, MO 63134.
- $300PlumbingCabled outside after drain (D-S cable outside after drain); 30-day warranty; paid in full.
- 30 Days Warranty
Coverage based on the record. Start date, ownership or occupancy, service territory, product or ordered options, transferability, and exclusions may affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Home Inspection
On December 13, 2022, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 4 other topics at 6809 Saint Olaf Drive, Berkeley, MO 63134.
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Plumbing,
- Roof,
- Windows
- Home InspectionWhole-home inspection of single-family property identified active roof leaks, HVAC ductwork issues, electrical deficiencies, and interior ceiling damage requiring repair before occupancy.
- ElectricalTree limbs are pushing on overhead power lines; one living room outlet has no power and needs repair or replacement; ungrounded two-prong outlets are present throughout the home.
- FoundationSlab-on-grade foundation with concrete block material and wood frame wall structure observed in satisfactory condition with no structural deficiencies noted.
- HVACHVAC flexible ductwork is twisted and does not heat or cool evenly per occupant; furnace filter is missing; AC compressor (International Comfort, Mfgd 2018) is functional but dirty and needs cleaning.
- PlumbingPVC supply pipes are satisfactory; Rheem 40-gallon electric water heater (Mfgd 2018) is functional with T&P relief valve present, but lacks a fuel disconnect.
- RoofExtensive damage to 3-tab shingled roof (estimated 15 years old) with tarpaper exposed, tattered roof tarp in place, active roof leaks present, and gutters clogged with leaves and debris.
- WindowsExterior windows (wood, vinyl, aluminum) and interior windows (double hung, fixed) are in satisfactory condition with no defects observed.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic Service — Unsealed flue vent letting outdoor air
On January 20, 2025, Arch Air Services documented HVAC at 6809 Saint Olaf Drive, Berkeley, MO 63134.
- $188HVACPerformed diagnostic and service call; sealed penetration and old flue vent to prevent outdoor air from entering the return air space, which was dropping heat delivery temperature — system running normally, new system and ductwork recommended.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Ductwork Installation — Supply duct modified
Arch Air Services documented HVAC at 6809 Saint Olaf Drive, Berkeley, MO 63134.
- $1,920HVACInstalled ductwork by modifying the supply air duct system, closing off old unused return air duct, opening soffit in kitchen to run a larger duct, connecting a 14" insulated flex duct from the soffit to the existing supply trunk in the attic, and removing old 6" supply flex duct with hole patching.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic Service — System undercharged; possible leak
On August 28, 2024, Arch Air Services documented HVAC at 6809 Saint Olaf Drive, Berkeley, MO 63134.
- $303HVACDiagnostic and service call performed; system found undercharged, 1 pound of 410A refrigerant added and balanced, possible leak identified in indoor coil and outdoor service valve, cap placed on outdoor valve.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Sewer Document
This record documents Sewer at 6809 Saint Olaf Drive, Berkeley, MO 63134.
- Sewer
This house had multiple sewer issues when owning it. It was recommended to service it at least once per year
Only original contributor can modify this entry
Create an account to manage your contributions over time
Recorded Jul 2024
This record, dated July 1, 2024, documents Appraisal at 6809 Saint Olaf Drive, Berkeley, MO 63134.
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.