Document (07/2026)
- Electrical
- Foundation
- HVAC
- Home Inspection
- Mold
- Pest
- Plumbing
- Roof
- Sewer
- Windows
On July 28, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 7 other topics at 6904 Dunleer, St. Louis, MO 63130.
- Record date
Available findings
- SewerWork status not resolved
Sewer lateral scope found a collapsed line at the cast-iron to clay pipe joint leaving the home, with soil filling the pipe requiring hydroflushing; additionally, the main sewer stack has a large hole in the cast-iron and needs repair or replacement.
- PestWork status not resolved
Wood Destroying Insect inspection at redacted, St. Louis, MO 63130: no visible evidence of wood destroying insects (termites, carpenter ants, carpenter bees, or reinfesting wood boring beetles) was observed; no action or treatment recommended.
- ElectricalWork status not resolved
Electric panel (Square D, 100-amp) has been ripped from the wall and most wiring removed — home needs complete re-wiring; vegetation is pushing on overhead power lines; smoke detectors are missing throughout.
- FoundationWork status not resolved
One large crack in the rear basement wall is causing moisture intrusion; front walkway is sunk and severely sloped and needs re-pouring; no structural issues identified overall.
- Home InspectionWork status not resolved
Whole-home inspection of a vacant, unoccupied single-family property identified numerous deficiencies across all systems including electrical, HVAC, plumbing, roof, foundation, and interior — no structural issues identified but many repairs needed.
- HVACWork status not resolved
1984 Emerson gas furnace has been stripped for parts and AC condenser has been totally removed — full HVAC system replacement needed; thermostat replacement also suggested.
- MoldWork status not resolved
Moisture and mildew present in the basement, originating from the large rear wall crack and ill-fitted basement windows.
- PlumbingWork status not resolved
Copper supply lines are cut and heavily corroded requiring full re-plumb; large hole present in cast iron main sewer stack needs repair or replacement; 1997 Richmond 40-gal gas water heater shows heavy rust and needs replacing; bathroom sink plumbing lines removed; bathroom and kitchen subfloors heavily damaged and need replacement.
- RoofWork status not resolved
Minor repairs needed on 10-year-old 3-tab shingled roof: small hole needs filling and gathered shingles need correction; two damaged areas present in living room ceiling likely related to roof condition.
- WindowsWork status not resolved
Broken window panes in three windows and missing glass panes in both front and rear storm doors need replacement; leaky window has caused damaged walls in bedroom requiring repair.