Hi, I'm 6904 Dunleer. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
← MAPSOURCE-BACKED RECORDS
6904 Dunleer
St. Louis, MO 6313038.6745°N, 90.3141°W
1Event
Contributed by:1 contributor

Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
Ask this homePowered by Fresh House property intelligence®
ASK ME ABOUT
RECORD SUMMARY
1 documented event
Contributed by: 1 contributor
First documented event: Jul 2026
Latest documented event: Jul 2026
First added to Fresh House: Jul 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
This page contains 1 documented record for 6904 Dunleer, St. Louis, MO 63130, dated in July 2026.
Home Inspection
Home Inspection Document
Inspected Jul 28, 2026Uploaded Jul 29, 20263 files
Documented from uploaded report
Property Professional Uploaded
By
Greensmith Home Inspection llcdocumented Electrical, Foundation, HVAC, and 7 other topics at 6904 Dunleer, St. Louis, MO 63130.
Scope
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Mold,
- Pest,
- Plumbing,
- Roof,
- Sewer,
- Windows
Contributor
worked on or inspected it- Home InspectionWhole-home inspection of a vacant, unoccupied single-family property identified numerous deficiencies across all systems including electrical, HVAC, plumbing, roof, foundation, and interior; no structural issues identified but many repairs needed.
- SewerSewer lateral scope found a collapsed line at the cast-iron to clay pipe joint leaving the home, with soil filling the pipe requiring hydroflushing; additionally, the main sewer stack has a large hole in the cast-iron and needs repair or replacement.
- Pestno action or treatment recommended
- ElectricalElectric panel (Square D, 100-amp) has been ripped from the wall and most wiring removed; home needs complete re-wiring; vegetation is pushing on overhead power lines; smoke detectors are missing throughout.
- FoundationOne large crack in the rear basement wall is causing moisture intrusion; front walkway is sunk and severely sloped and needs re-pouring; no structural issues identified overall.
- HVAC1984 Emerson gas furnace has been stripped for parts and AC condenser has been totally removed; full HVAC system replacement needed; thermostat replacement also suggested.
- MoldMoisture and mildew present in the basement, originating from the large rear wall crack and ill-fitted basement windows.
- PlumbingCopper supply lines are cut and heavily corroded requiring full re-plumb; large hole present in cast iron main sewer stack needs repair or replacement; 1997 Richmond 40-gal gas water heater shows heavy rust and needs replacing; bathroom sink plumbing lines removed; bathroom and kitchen subfloors heavily damaged and need replacement.
- RoofMinor repairs needed on 10-year-old 3-tab shingled roof: small hole needs filling and gathered shingles need correction; two damaged areas present in living room ceiling likely related to roof condition.
- WindowsBroken window panes in three windows and missing glass panes in both front and rear storm doors need replacement; leaky window has caused damaged walls in bedroom requiring repair.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.
PROPERTY COVERAGE
Home Inspection
✓ documentedRoof
✓ documentedPlumbing
✓ documentedSewer
✓ documentedFoundation
✓ documentedMold
✓ documentedElectrical
✓ documentedHVAC
✓ documentedPest
✓ documentedWindows
✓ documentedRadon
undocumentedAppraisals
undocumented