On July 3, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 7 Santa Cruz Drive, Florissant, MO 63031.
- Record date
Available findings
- PestWork status not resolved
Wood destroying insect inspection found visible evidence of termite infestation in a dead tree in the backyard; recommendation is to either remove the tree or perform termite treatment to the home.
- Home InspectionWork status not resolved
Whole-home inspection of single-family property identified multiple deficiencies including termite activity, dry-rotted deck, basement wall moisture/mildew, end-of-life HVAC, missing GFCI protection in multiple locations, no smoke detectors, and dead outlets in the rear addition.
- PestWork status not resolved
Dead tree in backyard is infested with termites that are beginning to chew on wood landscape timbers; no termite presence observed to the structure itself — inspector recommends removing the tree and affected timbers or performing termite treatment.
- RoofWork status not resolved
3-tab shingle roof estimated 15 years old is worn but functional; missing squirrel-proof screen around chimney vent needs replacement; tree limbs hanging over roof should be cut back.
- FoundationWork status not resolved
Cracks in the rear-facing unfinished basement wall have been repaired in a sloppy manner — moisture is coming in and beginning to mildew; cleanout door is also allowing moisture intrusion and needs properly sealed.
- HVACWork status not resolved
Lennox central split-system (furnace and 2.5-ton condenser), manufactured in 1990, is still functioning but approaching end of expected lifespan; HVAC ductwork needs insulation wrap as condensation is leaking onto basement ceiling tiles.
- ElectricalWork status not resolved
No smoke detectors present anywhere in the home; GFCI protection absent in basement bathroom, main-floor bathroom, kitchen, and basement laundry area; electric outlets in the rear addition have no power despite all breakers being on; 2-prong ungrounded outlets present throughout.
- PlumbingWork status not resolved
AO Smith 40-gallon natural gas water heater (manufactured 2017) is functioning properly; copper supply pipes and PVC waste pipes are in satisfactory condition; basement bathroom toilet water supply has been shut off and requires further evaluation.
- WindowsWork status not resolved
Broken window pane in the bathroom needs replacement; all other vinyl windows observed in satisfactory condition.