7 Santa Cruz Drive
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- Electrical · No smoke detectors, missing GFCI outlets, and dead outlets found · 2026
- HVAC · Heating and cooling system from 1990 is near end of lifespan · 2026
- Foundation · Basement wall has moisture and mildew coming through cracked repairs · 2026
- Pest · Termite infestation found in backyard tree near home · 2026
- Roof · Aging roof with missing chimney screen and overhanging tree limbs · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 7 Santa Cruz Drive, Florissant, MO 63031, dated in July 2026.
Home Inspection Document
On July 3, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 7 Santa Cruz Drive, Florissant, MO 63031.
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Windows
- Home InspectionWhole-home inspection of single-family property identified multiple deficiencies including termite activity, dry-rotted deck, basement wall moisture/mildew, end-of-life HVAC, missing GFCI protection in multiple locations, no smoke detectors, and dead outlets in the rear addition.
- PestWood destroying insect inspection found visible evidence of termite infestation in a dead tree in the backyard; recommendation is to either remove the tree or perform termite treatment to the home.
- PestDead tree in backyard is infested with termites that are beginning to chew on wood landscape timbers; no termite presence observed to the structure itself — inspector recommends removing the tree and affected timbers or performing termite treatment.
- Roof3-tab shingle roof estimated 15 years old is worn but functional; missing squirrel-proof screen around chimney vent needs replacement; tree limbs hanging over roof should be cut back.
- FoundationCracks in the rear-facing unfinished basement wall have been repaired in a sloppy manner — moisture is coming in and beginning to mildew; cleanout door is also allowing moisture intrusion and needs properly sealed.
- HVACLennox central split-system (furnace and 2.5-ton condenser), manufactured in 1990, is still functioning but approaching end of expected lifespan; HVAC ductwork needs insulation wrap as condensation is leaking onto basement ceiling tiles.
- ElectricalNo smoke detectors present anywhere in the home; GFCI protection absent in basement bathroom, main-floor bathroom, kitchen, and basement laundry area; electric outlets in the rear addition have no power despite all breakers being on; 2-prong ungrounded outlets present throughout.
- PlumbingAO Smith 40-gallon natural gas water heater (manufactured 2017) is functioning properly; copper supply pipes and PVC waste pipes are in satisfactory condition; basement bathroom toilet water supply has been shut off and requires further evaluation.
- WindowsBroken window pane in the bathroom needs replacement; all other vinyl windows observed in satisfactory condition.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.