1155 Saint Matthew Drive

Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- HVAC · Gas furnace from 1974 is past its expected lifespan · 2026
- Electrical · Ungrounded 2-prong outlets found throughout the home · 2026
- Foundation · Cracks in basement walls and brick facade pulling away from wall · 2026
- Plumbing · Water heater from 1995 is past its expected lifespan · 2026
- Pest · Older termite damage found on front fascia; treatment recommended · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 1155 Saint Matthew Drive, Florissant, MO 63031, dated in July 2026.
Home Inspection Document
On July 7, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 6 other topics at 1155 Saint Matthew Drive, Florissant, MO 63031.
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Sewer,
- Windows
- Home InspectionWhole-home inspection of single-family property found no structural issues; deficiencies noted across HVAC, plumbing, electrical, pest, roof, foundation, and interior systems.
- SewerSewer lateral videoscope inspection found no damages or obstructions in the sewer lateral lines.
- PestVisible evidence of wood destroying insects found: older termite damage present on wood fascia; borate-based solution treatment recommended for front fascia corners.
- HVACArmstrong gas furnace manufactured in 1974 has reached end of expected lifespan; Concept 10 AC condenser manufactured in 2001 is aged but performing; both need cleaning and servicing by an HVAC technician.
- PlumbingGeneral Electric 40-gallon natural gas water heater manufactured in 1995 has reached end of expected lifespan; minor plumbing leak in basement bathroom caused by a loose fitting requires repair, along with damage to the basement ceiling.
- SewerBusted yard vent for the sewer lateral line observed and requires repair or replacement.
- Roof3-tab shingle roof estimated to be 10 years old was installed correctly and is in satisfactory condition; tree limbs touching the structure need to be trimmed.
- ElectricalRear exterior outlet is functional but must be replaced with a GFCI plug; 100-amp Eaton service panel is newer and appears functional; 2-prong ungrounded outlets are present throughout.
- FoundationCracks observed in basement walls should be sealed with urethane caulk; no moisture intrusion detected; brick exterior facade on the north side appears to be slightly pulling away from the wall and needs secured.
- PestOlder termite damage is present on the front fascia corners; treatment with a borate-based solution (such as Bora-Care) is recommended; treatment recommended unless seller proves prior treatment.
- WindowsFirst basement window located past the stairs is loose in its frame and requires securing; other windows have been painted over and need to be opened for safety.