Hi, I'm 712 Crestland Drive. I only speak from this property's source-backed records — 3 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
712 Crestland Drive
Across 3 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 3 documented records
Fresh House Property Summary
Highlights selected from 3 documented records for this property.
- HVAC · New furnace, condenser, evaporator coil, and thermostat installed · Sep 2026
- HVAC · Crawl space furnace removed and duct connection made to new system · Sep 2026
- HVAC · Four bedroom floor return air grills added as part of HVAC job · Sep 2026
- HVAC · HVAC diagnostic performed and R-22 refrigerant added · Aug 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 3 documented records for 712 Crestland Drive, Ballwin, MO 63011, dated in August 2026. The amount summary includes $13,443.92 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Refrigerant Service — Diagnostic and R-22 refrigerant added
- HVAC
Built from Housecall Pro data
- $565HVACPerformed a residential OT diagnostic and added R-22 refrigerant (2 lb max) to the HVAC system.
- HVACPhotograph shows the interior of an outdoor HVAC condenser unit with the access panel removed, revealing severely fouled condenser coil fins on multiple sides heavily coated with dirt, dust, debris, and organic matter; refrigerant line sets and a service tool are also visible.
- HVAC2TTR2042B1000AA, Serial No. 33326PW3F), manufactured August 2003, rated 208/230V, 1-phase, 60Hz, with HCFC-22 refrigerant
- HVACPhotograph shows the interior of a circular pipe or drain with heavy corrosion, rust staining, white mineral scaling/deposits, and debris accumulation along the pipe walls.
- HVACPhotograph shows severely deteriorated roofing felt/tar paper and delaminating wood sheathing substrate at the junction with a masonry wall, with the sheathing visibly breaking apart and separating from the roofing layer.
- HVACPhotograph shows a sewer camera monitor screen (1.5X zoom) displaying the interior of a pipe with visible root intrusion or fibrous debris on the left side and a dark horizontal obstruction band across the pipe.
- HVACPhotograph shows a yellow digital clamp multimeter with the display reading 0.275 A (lower row) and 1500 (upper row, range indicator), with red and black test leads connected, being used outdoors near visible wiring.
- HVACPhotograph shows a sewer/pipe camera monitor screen displaying the interior of a pipe with a visible joint or seam running vertically, rough granular deposit or scale buildup at the joint, and a small protrusion or lateral opening visible on the right pipe wall; screen overlay shows 93°F.
- HVACPhotograph shows a sewer camera monitor screen displaying the interior of a pipe with a visible joint offset and debris or buildup accumulation at the joint; two oval lateral openings or shadows are visible along the pipe wall; camera ambient temperature reads 93°F.
- HVACPhotograph shows the interior of a pipe as viewed on a sewer camera inspection monitor, displaying a pipe joint with visible mineral deposits or scaling along the pipe wall and two dark lateral openings visible in the pipe interior; camera temperature reads 93°F and a partial date stamp reads 07-11.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge HVAC service visit
- HVAC
Built from Housecall Pro data
- HVACHVAC service visit on August 12, 2026 at 712 Crestland Drive, Ballwin, with no service lines listed and no charge.
- HVAC · document contextPhotograph shows pink fiberglass batt insulation installed in an attic space, visible both above and below a white-painted structural member (ceiling joist or rafter), with wood roof framing visible in the background.
HVAC · document contextOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Ductwork — 3-ton A/C, 100k BTU furnace, new coil
- HVAC
Built from Housecall Pro data
- $12,879HVACSupplied and installed a 3-ton American Standard condenser, 100,000 BTU two-stage gas furnace, evaporator coil and Sensi Wi-Fi thermostat, with flue piping, pads, 30-amp disconnect, four bedroom floor return air grills, and removal of the crawl space furnace with duct connection.
- HVACPhotograph shows a boxed gas furnace in original shipping packaging; model number S8X2C100M5PSCB, serial number 26335JSDHG, 100,000 TUH input, assembled in USA.
- HVACPhotograph shows large sheet-metal HVAC ductwork with foil-faced insulation panels in a crawlspace, including a taped/patched section on the duct face, with exposed floor joists above and a bare dirt floor below.
- HVACcondenser coil fins visible in background
- HVACPhotograph shows a large application of gray patching compound (consistent with hydraulic cement or masonry filler) applied to a concrete basement or crawlspace wall surface, with a rectangular metal frame leaning against the wall and debris on the floor.
- HVACPhotograph shows a rectangular sheet metal duct box (plenum or transition) mounted vertically in a crawlspace, secured at the top with foil tape to the subfloor framing; the crawlspace floor is bare dirt with scattered debris and floor joists with piping visible in the background.
- HVACPhotograph shows an outdoor air conditioning condenser unit mounted on a concrete pad against wood-panel siding, with insulated refrigerant lines entering the wall and an electrical disconnect box mounted nearby.
- HVACPhotograph shows a large rectangular HVAC duct in a crawlspace with a visible seam transition from foil-insulated to bare black sheet metal, sealed with white mastic or tape at the joint.
- HVACPhotograph shows a rectangular sheet metal duct descending through the subfloor framing into a crawlspace, with foil/metallic duct tape applied around the perimeter seams and an X-brace pattern on the duct face panel; dirt crawlspace floor and wood framing members are visible in the background.
- HVACPhotograph shows an upflow gas furnace with a stainless steel flue pipe, a sheet metal air handler/coil cabinet above, copper refrigerant lines with insulation, a smart thermostat mounted on the unit, and associated gas and electrical piping in an exposed-framing utility space.
- HVACPhotograph shows a large rectangular sheet-metal HVAC plenum or air handler box with an X-brace face panel, sealed with foil tape labeled '181A-P/181B-FX', installed in a crawl space with a dirt/debris floor and visible floor joists above; a coil unit with corrugated fins is visible to the left.
- HVACPhotograph shows large sheet-metal HVAC trunk ductwork with a branch running through a low-clearance crawlspace; duct joints appear taped/sealed and electrical wiring is routed alongside the ductwork.
- HVACPhotograph shows a large cardboard box with green strapping tape bearing a product label identifying Model Number 5A7A4042A1000B and Serial Number 26141MKYGF, manufactured in the USA (Factory ID H15, Prod Line G), with a flammable materials warning symbol.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an HVAC outdoor unit, displaying R454B refrigerant with 123.0 psi low-side pressure, 290.5 psi high-side pressure, 12.8°F superheat, and 9.0°F subcooling.
- HVACPhotograph shows a UEi EM152 digital manometer connected to an HVAC unit displaying a negative static pressure reading of -0.85 inH2O, with the unit's wiring compartment visible in the background.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.