- HVAC · Air conditioner contactor replaced to restore cooling power · Sep 2026
- HVAC · Condenser fan motor and capacitor supplied during diagnostic visit · Nov 2025
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 716 Fernwood Terrace, Lake St. Louis, MO 63367, dated in November 2025. The amount summary includes $1,054.65 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Work — Condenser fan motor and capacitor
- HVAC
Built from Housecall Pro data
- $628HVACPerformed a diagnostic trip and supplied a condenser fan motor and capacitor.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Contactor Replacement — Air conditioner contactor replaced
- HVAC
Built from Housecall Pro data
- $427HVACReplaced the air conditioner contactor, which controls power to the cooling system, and a trip fee was charged.
- HVACPhotograph shows a heavily soiled and partially collapsed pleated HVAC air filter removed from its housing; the filter media is dark brown with accumulated dust and debris throughout, and the lower pleats are visibly deformed, indicating the filter is well past its service life and requires replacement.
- HVACPhotograph shows the open electrical compartment of an outdoor HVAC condenser unit, with a 2-pole definite purpose contactor (MLS 780 / 62750), a cylindrical run capacitor, multiple wiring connections, accumulated dust and cobwebs, and vegetation encroaching on the left side of the unit.
- HVACno work details, dates, or amounts are visible
- HVACPhotograph shows Fieldpiece app refrigerant measurements for R-410A system: suction pressure 101.8 psig, liquid pressure 327.8 psig, actual superheat 16.5°F, actual subcooling 10.0°F, suction temperature 48.8°F, liquid temperature 92.0°F.
- HVACPhotograph shows standing water pooled across a dark, soiled floor beneath or beside a large appliance, with saturated debris including a cloth, a blue object, and a detergent packet visible; plumbing connections are partially visible at upper left.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.