Record 1Public property record

HVAC Work — Condenser fan motor and capacitor

  • HVAC

On November 25, 2025, JLM HEATING AND AIR CONDITIONING documented HVAC at 716 Fernwood Terrace, Lake St. Louis, MO 63367.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$628

    Performed a diagnostic trip and supplied a condenser fan motor and capacitor.

Record 2Public property record

HVAC Contactor Replacement — Air conditioner contactor replaced

  • HVAC

On September 11, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 716 Fernwood Terrace, Lake St. Louis, MO 63367.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$427

    Replaced the air conditioner contactor, which controls power to the cooling system, and a trip fee was charged.

  • HVACWork status not resolved

    Photograph shows a heavily soiled and partially collapsed pleated HVAC air filter removed from its housing; the filter media is dark brown with accumulated dust and debris throughout, and the lower pleats are visibly deformed, indicating the filter is well past its service life and requires replacement.

  • HVACWork status not resolved

    Photograph shows the open electrical compartment of an outdoor HVAC condenser unit, with a 2-pole definite purpose contactor (MLS 780 / 62750), a cylindrical run capacitor, multiple wiring connections, accumulated dust and cobwebs, and vegetation encroaching on the left side of the unit.

  • HVACWork status not resolved

    no work details, dates, or amounts are visible

  • HVACWork status not resolved

    Photograph shows Fieldpiece app refrigerant measurements for R-410A system: suction pressure 101.8 psig, liquid pressure 327.8 psig, actual superheat 16.5°F, actual subcooling 10.0°F, suction temperature 48.8°F, liquid temperature 92.0°F.

  • HVACWork status not resolved

    Photograph shows standing water pooled across a dark, soiled floor beneath or beside a large appliance, with saturated debris including a cloth, a blue object, and a detergent packet visible; plumbing connections are partially visible at upper left.