- HVAC · AC system received a diagnostic service visit · Jun 2026
- HVAC · Refrigerant readings flagged outside normal operating range · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 7309 Brunswick Avenue, St. Louis, MO 63119, dated in June 2026. The amount summary includes $284 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Diagnostic Service — plus 1.5 hrs labor
- HVAC
Built from Housecall Pro data
- $284HVACPerformed a residential diagnostic service and 1.5 hours of labor at the service address.
- HVACPhotograph shows the interior of a furnace cabinet with a green control board labeled 'SOFTWARE ID PC 0180-0650 V02' and thermostat terminal connections (W, R, G, B/C, Y/Y1) with multiple colored wires bundled and routed to the terminal strip.
- HVACFieldpiece app refrigerant side measurements show R-410A with suction pressure 103.6 psig, liquid pressure 407.5 psig, actual superheat 1.5°F, and actual subcooling 3.3°F; air side diagnostics show no data connected.
- HVACPhotograph shows an outdoor air conditioning condenser unit with a louvered metal cabinet, mounted on a concrete pad (embossed '30 X 30 X 2'); grass and weeds are visible around the base of the unit.
- HVACPhotograph shows an outdoor air conditioning condenser unit with louvered side panels heavily fouled with dirt, grass clippings, and organic debris, substantially obstructing airflow through the coil fins; unit sits on a concrete pad surrounded by vegetation.
- HVACFieldpiece refrigerant side measurements for R-410A show suction pressure 115.5 psig, discharge pressure 349.4 psig, actual superheat 22.2°F, and actual subcooling 1.9°F; app warns that highlighted values are outside the normal operating range.
- HVACFieldpiece app refrigerant side measurements show R-410A with suction pressure 103.7 psig (vapor saturation 33.2°F) and liquid pressure 407.1 psig (liquid saturation 117.7°F); actual superheat and subcooling are not displayed (link tool not connected for temperature probes).
- HVACPhotograph shows galvanized round ductwork with a wye branch fitting, loose multi-colored electrical wires running alongside the ducts, and a handheld instrument (yellow/green) resting on a flat duct surface in what appears to be a basement or utility area.
- HVACPhotograph shows the exterior louvered panel of an outdoor HVAC unit with heavy dirt and debris accumulation on the vents; a power drill is visible nearby suggesting active service work.