- HVAC · AC evaporator piston coil replaced due to sediment and lineset issues · Jul 2025
- HVAC · Furnace inducer assembly replaced after broken fan blade found · Dec 2025
- HVAC · AC service found severely clogged evaporator coil and low refrigerant · Jul 2025
- HVAC · AC service call found coil new, blower and charge good after cleaning · Jun 2026
- HVAC · AC service found dirty filter and low amp draw; recheck recommended · Apr 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 5 documented records for 7528 Cory Place, St. Louis, MO 63133, dated from July 2025 through June 2026. The amount summary includes $2,985.70 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Clogged evaporator coil, low refrigerant
- HVAC
Built from Housecall Pro data
- $219HVACService call for central AC not cooling; found severely clogged evaporator coil restricting airflow and refrigerant below optimal at the outdoor condensing unit.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Piston Coil Replacement — 14" piston coil replaced
- HVAC
Built from Housecall Pro data
- $2,000HVACReplaced 14" piston coil with extended labor because unforeseen condensing unit issues and a large amount of sediment/oil in the lineset made the install take longer than expected.
- HVACa measuring tape alongside the unit indicates approximate unit dimensions
- HVACPhotograph shows a vertical air handler unit installed in a basement, with copper refrigerant lines, a black accumulator/filter drier component at the top, a green condensate drain hose, and sheet metal ductwork connected above; a return air filter access panel is visible to the right.
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Furnace Service Call — Broken inducer fan blade
- HVAC
Built from Housecall Pro data
- $481HVACService call for a furnace making a high-pitched whirring noise at start-up; found debris and a broken fan blade in the fan and supplied a Goodman OEM inducer assembly.
- HVACPhotograph shows the interior of a gas furnace with the draft inducer/blower housing exposed, exhibiting heavy dust and lint accumulation around the circular inducer assembly; a gas valve with an ON/OFF switch and multiple wiring harnesses are also visible.
- HVACthe unit appears dusty with debris visible at the base
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Low amps: 4.6A vs 11.2A required
- HVAC
Built from Housecall Pro data
- $99HVACAC service call: cleaned the outside condensing unit, checked pressures (good), and found the system drawing 4.6A against the required 11.2A; only issues found were a dirty filter, low amps and a dirty condensing unit, with a recheck on a hot day recommended.
- HVACPhotograph shows a 20x20x1 FPR 5 air filter leaning against an HVAC air handler unit, with a return air grille visible adjacent; surrounding floor area shows debris and staining.
- HVACPhotograph shows a Rheem outdoor condenser unit (Model RA1324BJ1NA, Serial W291934680, manufactured 07/2019) with heavy debris, dust, and cobwebs accumulated on the top edge and around the data plate; unit uses R410A refrigerant at 208/230V, 1-phase.
- HVACPhotograph shows a gas forced-air furnace in a basement connected to a large sheet metal plenum above; the flue/exhaust pipe elbow on the left side of the unit shows visible rust and corrosion at the connection.
- HVAChigh-side 184.7 Psig with 9.8°F subcooling and 64.6 LSAT center readings show ODDB 56.5, SLT 59.2, LLT 54.8
- HVACPhotograph shows an outdoor air conditioning condenser unit on a concrete pad with heavy dirt and debris buildup on the coil fins and housing; a red plastic cup is resting on top of the unit and a disconnect box is mounted on the adjacent exterior wall.
- HVACPhotograph shows a 20x20x1 HVAC air filter being held up, with the filter media heavily coated in dark dust, debris, and lint accumulation indicating significant clogging and need for replacement.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Cleaned outdoor unit; charge good
- HVAC
Built from Housecall Pro data
- $187HVACService call for AC not keeping up; cleaned the outdoor unit and found the coil new, blower and filter good, and charge good.