HVACCompleted work$99
AC service call: cleaned the outside condensing unit, checked pressures (good), and found the system drawing 4.6A against the required 11.2A; only issues found were a dirty filter, low amps and a dirty condensing unit, with a recheck on a hot day recommended.
HVACWork status not resolved
Photograph shows a 20x20x1 FPR 5 air filter leaning against an HVAC air handler unit, with a return air grille visible adjacent; surrounding floor area shows debris and staining.
HVACWork status not resolved
Photograph shows a Rheem outdoor condenser unit (Model RA1324BJ1NA, Serial W291934680, manufactured 07/2019) with heavy debris, dust, and cobwebs accumulated on the top edge and around the data plate; unit uses R410A refrigerant at 208/230V, 1-phase.
HVACWork status not resolved
Photograph shows a gas forced-air furnace in a basement connected to a large sheet metal plenum above; the flue/exhaust pipe elbow on the left side of the unit shows visible rust and corrosion at the connection.
HVACWork status not resolved
high-side 184.7 Psig with 9.8°F subcooling and 64.6 LSAT center readings show ODDB 56.5, SLT 59.2, LLT 54.8
HVACWork status not resolved
Photograph shows an outdoor air conditioning condenser unit on a concrete pad with heavy dirt and debris buildup on the coil fins and housing; a red plastic cup is resting on top of the unit and a disconnect box is mounted on the adjacent exterior wall.
HVACWork status not resolved
HVACWork status not resolved
Photograph shows a 20x20x1 HVAC air filter being held up, with the filter media heavily coated in dark dust, debris, and lint accumulation indicating significant clogging and need for replacement.