On July 1, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 7720 Horatio Drive, St. Louis, MO 63121.
- Record date
Available findings
- PestWork status not resolved
WDI inspection found older, common termite damage on rear patio handrails; treatment recommended by spraying the affected area with a borate-based solution.
- Home InspectionWork status not resolved
Whole-home inspection of 7720 Horatio Dr, Saint Louis, MO 63121 identified multiple deficiencies including end-of-life HVAC, termite damage, missing smoke detectors, missing GFCI protection, and a rusted water heater inlet valve, with the home otherwise in generally good condition and no structural issues observed.
- PestWork status not resolved
Older termite damage is present on the rear patio wood railings; treatment with a borate-based solution (such as BoraCare) is recommended to kill existing termites and prevent future attacks.
- WindowsWork status not resolved
Damaged window on the west side of the home requires repair, and caulking around doors and windows is needed throughout.
- HVACWork status not resolved
The HVAC system is functioning but is at the end of its expected lifespan — the gas furnace (Amana) was manufactured in 1998 and the AC condenser (Goodman, 2-ton) in 1994; annual cleaning and servicing by a licensed contractor is required, and a kitchen exhaust hood above the gas range is absent and should be installed.
- PlumbingWork status not resolved
The gas water heater (Rheem, manufactured 2024, 40-gallon natural gas) is functioning properly, but one rusted inlet valve requires replacement.
- RoofWork status not resolved
Architectural shingle roof is estimated to be approximately 1 year old, recently installed, and is in satisfactory condition with ridge vents, metal flashings, and gutters all functioning properly.
- ElectricalWork status not resolved
Smoke detectors are not present throughout the home and should be installed; a GFCI-protected outlet is missing in the basement laundry area and requires installation; the 100-amp Eaton service panel is functional.
- FoundationWork status not resolved
The concrete block foundation is in good shape with no structural issues observed; missing mortar should be replaced as needed for preventive maintenance.