Property records for 810 Edgar Road, Webster Groves, MO 63119

All 8 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 8.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Service Invoice — No-charge HVAC service visit

  • HVAC

On April 17, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 810 Edgar Road, Webster Groves, MO 63119.

Record date

Available findings

  • HVACCompleted work
  • HVACWork status not resolved
Record 2Public property record

HVAC Replacement Estimate — 2.5-ton Lennox A/C and coil options

  • HVAC

On April 17, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 810 Edgar Road, Webster Groves, MO 63119.

Record date

Available findings

  • HVACEstimate or proposed work$6,933

    Estimate for two options for a 2.5-ton Lennox air conditioner and evaporator coil replacement, a standard Merit model and an Elite 16 SEER model, including condenser pad, disconnect, materials and labor; both options expired.

Record 3Public property record

HVAC Replacement Estimate — 3 Lennox furnace + A/C options, expired

  • HVAC

On April 17, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 810 Edgar Road, Webster Groves, MO 63119.

Record date

Available findings

  • HVACEstimate or proposed work$12,156

    Estimate for three options replacing the furnace and 2.5-ton air conditioner with Lennox equipment, coil, thermostat, and install materials; all options expired and none approved.

Record 4Public property record

HVAC Replacement Estimate — 3 Lennox furnace + A/C options, expired

  • HVAC

On April 17, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 810 Edgar Road, Webster Groves, MO 63119.

Record date

Available findings

  • HVACEstimate or proposed work$12,156

    Estimate for three HVAC replacement options at 810 Edgar Road, each with a Lennox furnace, air conditioner, coil, thermostat and install materials; all options are expired and none approved.

Record 5Public property record

HVAC Furnace Replacement Estimate — 4 gas furnace replacement

  • HVAC

On April 19, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 810 Edgar Road, Webster Groves, MO 63119.

Record date

Available findings

  • HVACEstimate or proposed work$4,593

    Estimate for gas furnace replacement with four options (standard 93% 70,000 BTU, Elite 70,000 BTU, Silver 96%, Gold 2-stage 97%), including labor, PVC venting, install materials and filter rack; all options expired.

Record 6Public property record

HVAC Estimate — 2.5-ton A/C and coil, 2 options

  • HVAC

On April 19, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 810 Edgar Road, Webster Groves, MO 63119.

Record date

Available findings

  • HVACEstimate or proposed work$6,444

    Estimate for two options to install a 2.5-ton air conditioner and cased evaporator coil, a 14 SEER option and a 16 SEER option, including labor, condenser pad and 30-amp disconnect.

Record 7Public property record

HVAC Furnace Replacement Estimate — Two 70,000 BTU gas furnace

  • HVAC

On April 19, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 810 Edgar Road, Webster Groves, MO 63119.

Record date

Available findings

  • HVACEstimate or proposed work$5,752

    Estimate for replacement of a gas furnace with two options: a standard 93% 70,000 BTU single-stage furnace or an elite two-stage 70,000 BTU furnace, including labor, PVC venting, install materials and a filter rack.

Record 8Public property record

HVAC Installation — 96% 2-stage furnace + 2.5-ton A/C

  • HVAC

On April 23, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 810 Edgar Road, Webster Groves, MO 63119.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$11,116

    Installed a 2.5-ton Silver 14 series air conditioner, a 60k 96% 2-stage gas furnace, a 3-ton cased evaporator coil, a Sensi Wi-Fi thermostat, condenser pad, 30-amp disconnect, and PVC condensate piping with install materials and labor.

  • HVACWork status not resolved

    Photograph shows a basement mechanical room with a high-efficiency gas furnace (dark gray cabinet with digital display), large sheet metal supply ductwork overhead, PVC flue/condensate pipes, copper refrigerant lines, and a wall-mounted humidifier or air handler unit to the left.

  • HVACWork status not resolved

    Photograph shows two outdoor HVAC condensing units mounted on concrete pads against a brick exterior wall, with an electrical disconnect box mounted nearby, refrigerant lines visible at the base, and significant overgrown vegetation and leaf debris accumulating around both units.

  • HVACWork status not resolved

    Photograph shows an open HVAC air handler/furnace with a UEI EM152 digital manometer attached and displaying a reading of 7.08, with internal blower motors and wiring visible.

  • HVACWork status not resolved

    Photograph shows two outdoor air conditioning condensing units mounted on concrete pads along the exterior brick wall, with refrigerant line sets, electrical conduit, and a disconnect box visible; overgrown vegetation and leaf debris surround the units.

  • HVACWork status not resolved

    Photograph shows a UEI PDT650 pocket thermometer clipped to a sheet metal HVAC duct or air handler enclosure, displaying a reading of 73°F, with insulated flexible ductwork visible in the background.

  • HVACWork status not resolved

    Photograph shows a UEi EM152 digital differential pressure manometer displaying a reading of -053, connected via clear tubing to what appears to be an HVAC air handler cabinet; the word 'COOL' is annotated in red at the bottom of the image.

  • HVACWork status not resolved

    Photograph shows a Testo 557 digital manifold gauge connected to an outdoor condenser unit, displaying R454B refrigerant readings: superheat (SH) 20.4°F, subcooling (SC) 10.3°F, low-side pressure 107.3 psig, and high-side pressure 282.4 psig.

  • HVACWork status not resolved

    Photograph shows a UEI PDT650 pocket thermometer clipped to a metal pipe reading 114°F, positioned adjacent to foil-taped HVAC ductwork labeled AF 099 / 181A-P / 181B-FX.

  • HVACWork status not resolved

    Photograph shows a UEI EM152 digital manometer connected to an HVAC unit interior displaying a differential pressure reading of -1.69; HVAC wiring and components are visible in the background.

  • HVACWork status not resolved

    a second condenser unit is partially visible to the left

  • HVACWork status not resolved

    Photograph shows a UEI PDT650 pocket thermometer reading 104.7°F placed on a sheet metal supply duct sealed with foil tape (AF 099 / 181B-FX), with a pipe running across the duct surface.

  • HVACWork status not resolved

    Photograph shows a UEI EM152 differential pressure manometer displaying a reading of -870, connected via two probe hoses to what appears to be an HVAC unit cabinet.

  • HVACWork status not resolved

    Photograph shows a UEi EM152 digital differential pressure manometer connected via two clear tubes to an HVAC unit, displaying a reading of -0.66.

  • HVACWork status not resolved
  • HVACWork status not resolved

    Photograph shows a UEI EM152 digital manometer displaying a reading of -7.48, being used near mechanical piping and HVAC equipment.