- HVAC · New furnace installed with gas, electrical, and flue work · Aug 2025
- HVAC · AC coil and condenser proposed for replacement · Jun 2024
- HVAC · Furnace control board replaced after house flooding caused water damage · Mar 2026
- HVAC · Furnace control board replaced due to incompatible aftermarket blower motor · Aug 2025
- HVAC · Basement water pooled from frozen coil; drain lines cleared and filter checked · Aug 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 7 documented records for 8213 John Place, St. Louis, MO 63114, dated from June 2024 through August 2026. The amount summary includes $9,179.11 in completed work across HVAC, $139 in estimates; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Bad compressor; AC replacement recommended
- HVAC
Built from Housecall Pro data
- HVACUpon arrival found the compressor to be bad and recommended replacing the AC.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Condenser and Coil Replacement — 4-ton condenser and coil
- HVAC
Built from Housecall Pro data
- $3,924HVACWork performed: Coil/Condenser 4 Ton R410A System (We propose to install the following equipment in above listed unit); Coil/Condenser (This quote includes, fused disconnect, electrical whip); Payment/Terms; Equipment Warranty; Terms and Conditions.
Documented warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
What this warranty covers
- parts
· source
“manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Faulty furnace control board, special order
- HVAC
Built from Housecall Pro data
- $139HVACNormal hours service call and labor; found indoor unit not functioning due to a faulty control board, which is a special order part due to the age of the furnace.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Incompatible aftermarket blower motor found
- HVAC
Built from Housecall Pro data
- $776HVACService call found the system not functioning properly due to an incompatible aftermarket high efficiency blower motor; York control center was replaced with a factory OEM ECM control board, and the customer declined the blower motor replacement.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Installation — Rheem 95% 84,000 BTU furnace installed
- HVAC
Built from Housecall Pro data
- $3,900HVACInstalled a Sure Comfort by Rheem 95% 84,000 BTU furnace (M/N S95TC0851521MSA), including sheet metal work, new gas shut off and gas pipe, new electrical switch and power, and flue work to existing lines.
- HVACPhotograph shows the interior of a gas furnace with access panel open, revealing the inducer/draft blower motor, gas valve (ON/OFF switch visible), heat exchanger burner tubes, multi-colored wiring harness, condensate drain assembly, and PVC flue exhaust piping.
- HVACPhotograph shows a forced-air furnace/air handler unit mounted on a concrete block pad in an unfinished basement, with a large sheet-metal supply plenum and branching ductwork overhead, and PVC pipes (condensate or flue) running vertically alongside the unit.
- HVACPhotograph shows the interior of a gas furnace with the access panel removed, revealing an active burner assembly with blue flames burning across multiple burner ports, red electrical wiring, a gas valve/manifold assembly, and a gas supply pipe.
- HVACPhotograph shows a high-efficiency gas furnace (gray cabinet with blue logo) installed on cinder blocks in an unfinished basement, connected to sheet metal ductwork above and equipped with two white PVC flue/intake pipes routed upward, flexible metallic conduit, and a condensate drain line.
- HVACPhotograph shows the interior of a high-efficiency gas furnace with access panel removed, revealing burners, inducer/draft motor, gas valve, wiring harness, condensate trap, and PVC flue/condensate piping; reddish-brown staining or residue is visible on the white PVC pipe at the upper right.
- HVACPhotograph shows a large gray metal air handler unit installed in a basement/mechanical room, connected to sheet metal supply ductwork above via foil-taped plenum, with a white PVC condensate drain line running along the unit's side, and the unit elevated on a concrete block pad.
- HVACPhotograph shows an upflow gas furnace mounted on cinder blocks in an unfinished basement, connected to a sheet-metal supply air plenum, with two white PVC combustion/flue pipes routed diagonally upward, a flexible metallic gas line, and a red shutoff valve visible to the left.
- HVACmode options visible include Cool, Off, and Heat with Fan On/Auto settings
- HVACPhotograph shows a digital thermostat mounted on a white interior wall, with dark wood-tone flooring and white baseboard trim visible throughout the room.
Documented warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
What this warranty covers
- parts
· source
“All equipment installed by Contractor comes with a manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Control Board Replacement — Control board replaced, water damage
- HVAC
Built from Housecall Pro data
- $425HVACReplaced factory control board due to water damage from house flooding, with a normal hours service call and labor performed.
- HVACPhotograph shows a close-up of an HVAC control board populated with resistors, capacitors, diodes, and a white SCHRACK RT1134012 12VDC relay (rated 12A/250VAC), along with terminal connectors labeled NEUTRALS and P2.
- HVACPhotograph shows the solder side of a green printed circuit board with visible blue-green corrosion on multiple solder pads and copper traces, along with brown burn-like deposits at several solder joint clusters in the upper and mid-center areas of the board.
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Frozen coil from low thermostat flooded basement
- HVAC
Built from Housecall Pro data
- $154HVACService call found water pooled in basement from a frozen coil caused by a low thermostat setting; drain lines were cleared, filter and system charge checked, equipment operating as intended, and the open basement window was closed most of the way but is stuck.