Hi, I'm 866 San Sebastian Drive. I only speak from this property's source-backed records — 3 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
866 San Sebastian Drive
Across 3 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 3 documented records
Fresh House Property Summary
Highlights selected from 3 documented records for this property.
- HVAC · Furnace, air conditioner, evaporator coil, and humidifier replaced · Oct 2026$13k
- HVAC · Wi-Fi thermostat and new flue pipe installed with HVAC system · Oct 2026
- HVAC · Outdoor AC wall-mounted with line set and insulation supplied · Apr 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 3 documented records for 866 San Sebastian Drive, Fenton, MO 63026, dated from April 2026 through October 2026. The amount summary includes $13,951.50 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Air Conditioner Mounting — A/C wall mount with line set
- HVAC
Built from Housecall Pro data
- $1,452HVACAir conditioner wall mount with 36" mounting brackets and concrete hangers, line set and insulation supplied, and misc materials (nitrogen, brazing rod, copper fittings, vacuum pump, recovery, flush), with journeyman and apprentice labor.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge service call, no line items
- HVAC
Built from Housecall Pro data
- HVACPhotograph shows a forced-air gas furnace data plate rated at 80,000 BTU/HR input and 64,000 BTU/HR output, with a 1/3 HP motor, 35; 65°F temperature rise, and 0.50" W.C. max external static pressure; manufactured to ANSI Z21.47A / CAN/CGA-2.3A-1995 standards by York, Pennsylvania.
- HVACPhotograph shows a manufacturer data plate on a natural gas forced-air furnace, model P3HUA12N06401B, serial ENGM507024, rated 80,000 BTU/hr input and 64,000 BTU/hr output, 115V-1PH-60Hz, 1/3 HP motor.
- HVACWFKM029597, rated 208; 230V 1PH 60HZ, using R22 refrigerant with a factory charge of 5 lbs 15 oz total charge fields are blank (installer-fill)
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Installation — 3-ton A/C + 100k BTU furnace + humidifier
- HVAC
Built from Housecall Pro data
- $12,500HVACSupplied and installed a 3-ton American Standard 17 SEER2 air conditioner, 100,000 BTU gas furnace, evaporator coil, Sensi Wi-Fi thermostat, flue pipe, and AprilAire 700M power humidifier.
- HVAC5PXCC005AS3HAAA, Serial No. 26302JA35Q) assembled in the USA, with a refrigerant leak detector alarm code sticker also visible on the cabinet
- HVACPhotograph shows an evaporator coil data plate (Model No. 5PXCC005AS3HAAA, Serial No. 26302JA35Q) labeled R-454B ONLY, with an active alarm code legend and a flammable refrigerant warning label visible on the unit.
- HVACPhotograph shows an evaporator coil data plate (Serial No. 26302JA35G, assembled in USA) with a flammable refrigerant warning label specifying R-454B only, and a refrigerant alarm/sensor error legend visible on the unit housing.
- HVACPhotograph shows a cardboard box bearing a product label with Model Number S8V2C100M5PCBA, Serial Number 26255N01HG, assembled in USA; RFID EPC and Factory ID fields are blank.
- HVACunit is made in USA
- HVACa water heater is partially visible at right
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.