On July 21, 2022, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 8820 Cozens Avenue, Jennings, MO 63136.

Record date

Available findings

  • Electrical

    Older knob and tube wiring with taped joints is in use throughout the house; smoke detectors are not present; a weatherproof cover is missing from the exterior outlet on the east side; two-prong ungrounded outlets are in use; and tree limbs are pushing on overhead power lines.

  • Foundation

    Cracks are present in the concrete block foundation that have been repaired in a sloppy fashion; loose caulk should be removed and cracks properly sealed with urethane caulk.

  • Home Inspection

    Whole-home inspection of 8820 Cozens Ave., St. Louis, MO identified multiple deficiencies across electrical, plumbing, sewer, foundation, mold, HVAC, and interior systems requiring repair or further evaluation prior to occupancy.

  • HVAC

    The Lennox central split system furnace and AC compressor (estimated 5 years old) appear functional but are dirty and need to be cleaned and serviced by a licensed HVAC technician.

  • Mold

    Mold presence was observed in the northeast corner room of the basement, likely resulting from poorly repaired cracks in the block foundation; mold needs to be removed and all cracks completely sealed.

  • Plumbing

    Exterior faucet at rear corner is inoperable, and the clothes washing machine discharges waste water into an open floor drain rather than a proper drain connection cut into the nearby sewer stack.

  • Roof

    The 3-tab shingle roof (estimated 15 years old) is in satisfactory condition overall; a loose gutter on the front corner of the home needs to be secured.

  • Sewer

    Sewer lateral scope revealed an offset where two pipe sections have come loose with one section sitting several inches higher, and a foreign item is lodged at the offset — the intersection needs to be excavated and repaired to prevent future backups.

Record 2Public property record

Home Inspection Report — knob & tube wiring; mold in basement

  • Electrical
  • Foundation
  • HVAC
  • Home Inspection
  • Mold
  • Plumbing
  • Roof
  • Sewer

This record, dated July 21, 2022, documents Electrical, Foundation, HVAC, and 5 other topics at 8820 Cozens Avenue, Jennings, MO 63136.

Record date

Available findings

  • Electrical

    Older knob and tube wiring with taped joints is in use throughout the house, smoke detectors are not present, a weatherproof cover is missing from the exterior outlet on the east side, and two-prong ungrounded outlets are in use.

  • Foundation

    Cracks are present in the concrete block foundation that have been repaired in a sloppy fashion; loose caulk should be removed and cracks properly sealed with urethane caulk.

  • Home Inspection

    Whole-home inspection of single-family property at redacted identified multiple defects across plumbing, electrical, foundation, mold, HVAC, and sewer systems, with no structural deficiencies observed.

  • HVAC

    The Lennox central split system furnace and AC compressor appear functional but are estimated five years old, dirty, and need to be cleaned and serviced by an HVAC technician.

  • Mold

    Mold presence was observed in the northeast corner room of the basement, likely resulting from poorly repaired cracks in the block foundation; mold needs to be removed and all cracks completely sealed.

  • Plumbing

    Exterior faucet at rear corner is inoperable, and the clothes washing machine dumps waste water into an open floor drain requiring a proper drain connection cut into the nearby sewer stack.

  • Roof

    The 3-tab shingle roof is estimated 15 years old and in satisfactory condition, though a loose gutter on the front corner of the home needs to be secured.

  • Sewer

    A sewer lateral scope revealed an offset where two pipe sections have come loose with one sitting a few inches higher, and a foreign item is lodged at the offset; the intersection needs to be excavated and repaired.