- Electrical · Old knob-and-tube wiring and no smoke detectors found throughout home · 2022
- Sewer · Broken pipe offset with lodged debris needs excavation and repair · 2022
- Foundation · Foundation cracks were poorly repaired and need proper resealing · 2022
- Mold · Mold found in basement corner, needs removal and sealing · 2022
- Plumbing · Washing machine drains improperly into open floor drain · 2022
Ask this homePowered by Fresh House property intelligence®
Reading property memory…
RECORD SUMMARY
2 documented events
2 independent contributors
First recorded: Apr 2026
Most recent update: Apr 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
DOCUMENTED
Home Inspection
Inspected Jul 21, 2022 · uploaded Apr 28, 2026
Documented from uploaded report
Property Professional Uploaded
Scope
ElectricalFoundationHVACHome InspectionMoldPlumbingRoofSewer
Contributor
worked on or inspected it- Home InspectionWhole-home inspection of 8820 Cozens Ave., St. Louis, MO identified multiple deficiencies across electrical, plumbing, sewer, foundation, mold, HVAC, and interior systems requiring repair or further evaluation prior to occupancy.
- RoofThe 3-tab shingle roof (estimated 15 years old) is in satisfactory condition overall; a loose gutter on the front corner of the home needs to be secured.
- ElectricalOlder knob and tube wiring with taped joints is in use throughout the house; smoke detectors are not present; a weatherproof cover is missing from the exterior outlet on the east side; two-prong ungrounded outlets are in use; and tree limbs are pushing on overhead power lines.
- PlumbingExterior faucet at rear corner is inoperable, and the clothes washing machine discharges waste water into an open floor drain rather than a proper drain connection cut into the nearby sewer stack.
- SewerSewer lateral scope revealed an offset where two pipe sections have come loose with one section sitting several inches higher, and a foreign item is lodged at the offset — the intersection needs to be excavated and repaired to prevent future backups.
- FoundationCracks are present in the concrete block foundation that have been repaired in a sloppy fashion; loose caulk should be removed and cracks properly sealed with urethane caulk.
- MoldMold presence was observed in the northeast corner room of the basement, likely resulting from poorly repaired cracks in the block foundation; mold needs to be removed and all cracks completely sealed.
- HVACThe Lennox central split system furnace and AC compressor (estimated 5 years old) appear functional but are dirty and need to be cleaned and serviced by a licensed HVAC technician.
Fresh House generated structured findings from a documented professional record.
Only original contributor can modify this entry
Create an account to manage your contributions over time
DOCUMENTED
Home Inspection
Inspected Jul 21, 2022 · uploaded Apr 16, 2026
Community-uploaded
Scope
ElectricalFoundationHVACHome InspectionMoldPlumbingRoofSewer
- Home InspectionWhole-home inspection of single-family property at 8820 Cozens Ave., St. Louis, MO 63136 identified multiple defects across plumbing, electrical, foundation, mold, HVAC, and sewer systems, with no structural deficiencies observed.
- PlumbingExterior faucet at rear corner is inoperable, and the clothes washing machine dumps waste water into an open floor drain requiring a proper drain connection cut into the nearby sewer stack.
- ElectricalOlder knob and tube wiring with taped joints is in use throughout the house, smoke detectors are not present, a weatherproof cover is missing from the exterior outlet on the east side, and two-prong ungrounded outlets are in use.
- FoundationCracks are present in the concrete block foundation that have been repaired in a sloppy fashion; loose caulk should be removed and cracks properly sealed with urethane caulk.
- MoldMold presence was observed in the northeast corner room of the basement, likely resulting from poorly repaired cracks in the block foundation; mold needs to be removed and all cracks completely sealed.
- HVACThe Lennox central split system furnace and AC compressor appear functional but are estimated five years old, dirty, and need to be cleaned and serviced by an HVAC technician.
- SewerA sewer lateral scope revealed an offset where two pipe sections have come loose with one sitting a few inches higher, and a foreign item is lodged at the offset; the intersection needs to be excavated and repaired.
- RoofThe 3-tab shingle roof is estimated 15 years old and in satisfactory condition, though a loose gutter on the front corner of the home needs to be secured.
Fresh House generated structured findings from a documented professional record.
Hiding personal details before others can see this file. Check back shortly.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.
PROPERTY COVERAGE
Home Inspection
✓ documentedRoof
✓ documentedPlumbing
✓ documentedSewer
✓ documentedFoundation
✓ documentedMold
✓ documentedElectrical
✓ documentedHVAC
✓ documentedPest
undocumentedRadon
undocumentedAppraisals
undocumentedWindows
undocumented