- HVAC · Furnace high limit replaced and loose wiring repaired · Dec 2025
- HVAC · AC diagnosed as older system with clogged indoor coil and bent outdoor fins · May 2026
- HVAC · Pressure switch cleared of construction debris restoring heat · Dec 2025
- HVAC · Bedrooms found to have fewer supply vents than expected; duct cleaning suggested · Jul 2025
- HVAC · Estimate issued to replace indoor coil and outdoor condensing unit · Jun 2026$5.8k
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 10 documented records for 9834 Portage Drive, St. Louis, MO 63136, dated from July 2025 through June 2026. The amount summary includes $1,021 in completed work across HVAC, $5,823 in estimates; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Only 1 vent per bedroom; uneven airflow
- HVAC
Built from Housecall Pro data
- $89HVACNormal hours service call for air conditioning not cooling evenly; ductwork inspected in basement and only one vent found in each bedroom where two are expected, with duct cleaning suggested to check for airflow blockage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Seasonal Maintenance — Seasonal maintenance; all systems worked
- HVAC
Built from Housecall Pro data
- $89HVACSeasonal maintenance on a vacant unit: checked all system operations, which worked correctly, checked pressure hoses and wire connections, and cleaned the flame sensor; filter size 16x25x1.
- HVACPhotograph shows an HVAC air handler blower assembly with a squirrel cage blower wheel exhibiting significant dust and debris accumulation, an electric blower motor with a data plate label, multiple multi-colored electrical wires connected to the motor, and rust/mineral staining visible on the surrounding sheet metal housing.
- HVACPhotograph shows a squirrel-cage blower wheel inside an HVAC air handler housing with heavy dust and debris accumulation on the blades and surrounding sheet metal; a directional arrow is marked on the center hub and a small hole is visible in the housing sidewall.
- HVACwiring and tubing are visible in the upper compartment, and a data label is affixed to the lower front panel
- HVACPhotograph shows the interior of an HVAC air handler or furnace with the access panel removed, revealing a green control board, a heavily corroded/rusted transformer housing, a capacitor, and a large disorganized bundle of multi-colored wiring loose on the unit floor; interior sheet metal surfaces show rust staining and dirt accumulation.
- HVAChandwritten notation on the duct reads '16x25x1 filter' with an arrow indicating filter location, and a yellow service sticker is affixed to the duct
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Cleared debris from pressure switch lines
- HVAC
Built from Housecall Pro data
- $154HVACService call: system was not coming on due to construction debris in the pressure switch; cleared the pressure switch lines and the system worked as intended.
- HVACPhotograph shows a gas furnace with access panels removed, exposing the heat exchanger tubes, inducer motor, wiring harness, and control board area; a red LED indicator light is illuminated on the control board, and a heavily soiled air filter is visible on the left side of the unit.
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Heat Repair — Replaced high limit, repaired loose wiring
- HVAC
Built from Housecall Pro data
- $227HVACRepaired heat by replacing the high limit and repairing loose wiring; all systems were working as intended at completion of service.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge service visit
- HVAC
Built from Housecall Pro data
- HVACHeating and cooling service visit on December 9, 2025 with no services itemized and no charge.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — No heat return call
- HVAC
Built from Housecall Pro data
- HVACReturn service call for a no heat complaint.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Disconnect bumped off; AC power restored
- HVAC
Built from Housecall Pro data
- $154HVACService call for no AC: checked furnace and filter, found the outdoor disconnect lever bumped slightly out of the on position cutting power to the outdoor unit, turned it on and checked system charge; unit running as intended.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Two filters found in slot; AC not cooling
- HVAC
Built from Housecall Pro data
- $154HVACWork performed: Description (Tenant had ac it was just not cooling properly after inspecting the indoor unit); Labor (Labor Per Hour).
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Clogged indoor coil, bent fins
- HVAC
Built from Housecall Pro data
- $154HVACDiagnosed AC not keeping up, checked system and adjusted charge slightly; high side pressure points to a clogged damaged indoor coil and outdoor fins are bent, system is older and at end of life.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Condensing Unit Estimate — 2.5-ton condensing unit and coil
- HVAC
Option: Option #1 $5,823 (declined)
Built from Housecall Pro data
- $5,823HVACEstimate for Option #1: Coil/Condensing Unit Install Description (This quote includes, fused disconnect, electrical whip and pad for condensing), Terms and Conditions, 2.5 Ton 13.4 SEER2 R454B W/TXV Coil (We propose to install the following equipment in your home), Payment Terms Net 30, Equipment Warranty.
Documented warrantyfive-year / ten-year / twenty-yearFrom estimateView details
What this warranty covers
- parts
· source
“All equipment installed by Contractor comes with a manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an estimate. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.