9835 Portage Drive

Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- Electrical · Sparking outlet and ungrounded two-prong outlets found throughout home · 2026
- HVAC · Heating and cooling system over 10 years old, needs annual servicing · 2026
- Sewer · Sewer lines flowing with minor scaling, no major issues found · 2026
- Plumbing · Cracked sewer stack leaking, sump pump broken with sparking outlet · 2026
- Roof · Cracked roof vent stack with lifted flashing needs replacement · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 9835 Portage Drive, St. Louis, MO 63136, dated in August 2026.
Home Inspection Document
On August 6, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 9835 Portage Drive, St. Louis, MO 63136.
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Sewer
- Home InspectionWhole-home inspection of single-family property found the home generally in good condition with no structural issues; deficiencies noted include a cracked cast-iron sewer stack, inoperable sump pump with sparking outlet, cracked roof vent stack, and failed tub diverter valve.
- SewerSewer lateral lines are open and flowing; light scaling is present on the cast-iron portion but not enough to require cabling — no issues flagged.
- PestVisual WDI inspection of SFR/Attached Carport at 9835 Portage Drive found no visible evidence of wood destroying insects (termites, carpenter ants, carpenter bees, or reinfesting wood boring beetles); no treatment recommended.
- Electrical100-amp Eaton service panel in basement is functional; 2-prong ungrounded outlets are present throughout; a functioning smoke detector should be installed in the basement near gas appliances.
- FoundationPoured concrete basement foundation is in satisfactory condition with no moisture detected and no deficiencies observed in basement walls or stairs; perimeter insulation is absent and adding insulation is suggested.
- HVACGoodman central split system (manufactured 2015, 2.5-ton condenser) is functioning correctly but requires annual cleaning and servicing as it is over 10 years old.
- PlumbingA crack in the main sewer stack's cast-iron section is causing water to leak onto the basement floor; the sump pump is inoperable with a full sump well and a sparking outlet (both need replacement); the water heater expansion tank has a rusted fitting needing replacement; and the tub diverter valve has failed, requiring tub faucet replacement.
- RoofOne metal roof exhaust vent stack is cracked, has been taped, and has lifted flashing — needs replacement; tree limbs are contacting the structure and should be cut back.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.