9938 Duke Drive
Fresh House Property Summary
Generated from 6 documented records on this property page.
- Electrical · Both bedroom smoke detectors are broken and need replacing · 2023
- HVAC · Full new HVAC system installed including furnace and air conditioner · 2024$6.4k
- Foundation · Concrete slab foundation is in satisfactory condition · 2023
- Mold · Active mold in rear bedroom ceiling needs remediation · 2023
- Appraisals · Appraisal recorded at $132,000 · 2024
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
- Home InspectionWhole-home inspection of single-family property at 9938 Duke Dr found the home in generally good shape with no structural deficiencies; actionable items include window caulking, soffit/fascia repair, gutter cleaning, inoperable smoke detectors, mold in rear bedroom ceiling, and damage to middle bedroom ceiling.
- WindowsVinyl windows are satisfactory overall but caulking is needed around windows as observed.
- Roof3-tab shingle and roll roofing estimated 5–10 years old in satisfactory condition; damaged soffit on west side and damaged fascia on south end require repair; gutters need leaves and debris removed.
- ElectricalBoth smoke detectors in bedrooms are inoperable and need to be replaced; 100-amp Eaton service panel in storage room appears functional with satisfactory breakers.
- MoldMold is present in the rear bedroom ceiling; per occupant, owners previously removed more extensive mold but it has returned and needs remediation; a large hole in the soffit at the corresponding exterior is identified as the likely moisture source.
- HVACCentral split system with Ruud forced-air furnace (manufactured 2006) and Goodman 2-ton condenser (manufactured February 2019) both appear functional and satisfactory.
- PlumbingPEX supply piping in satisfactory condition; Kenmore 40-gallon natural gas water heater (manufactured 2003) appears functional with T&P relief valve and discharge pipe present.
- FoundationSlab-on-grade poured concrete foundation and wood-frame wall structure are both in satisfactory condition with no structural deficiencies observed.
Fresh House generated structured findings from a documented professional record.
Only original contributor can modify this entry
Create an account to manage your contributions over time
- $6,394HVACInstalled complete HVAC system including new Run Tru 80% gas furnace, 2.5-ton Run Tru 13 SEER air conditioner with matching cased insulated evaporator coil, condensate pump with drain line, and Emerson digital thermostat; installation included new condenser pad, electrical wire whip, electrical disconnect box, sheet metal plenum transition, condensate drain system, reconfigured gas line, external air filter rack, and removal of existing system.
Fresh House generated structured findings from a documented professional record.
Coverage based on the record. Start date, transferability, and exclusions may vary.
Only original contributor can modify this entry
Create an account to manage your contributions over time
- $89HVACDiagnostic and service call performed at residential property on Duke Dr, St. Louis, MO.
Fresh House generated structured findings from a documented professional record.