On March 10, 2023, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 9938 Duke Drive, St. Louis, MO 63136.
- Record date
Available findings
- Roof
3-tab shingle and roll roofing estimated 5–10 years old in satisfactory condition; damaged soffit on west side and damaged fascia on south end require repair; gutters need leaves and debris removed.
- Electrical
Both smoke detectors in bedrooms are inoperable and need to be replaced; 100-amp Eaton service panel in storage room appears functional with satisfactory breakers.
- Mold
Mold is present in the rear bedroom ceiling; per occupant, owners previously removed more extensive mold but it has returned and needs remediation; a large hole in the soffit at the corresponding exterior is identified as the likely moisture source.
- HVAC
Central split system with Ruud forced-air furnace (manufactured 2006) and Goodman 2-ton condenser (manufactured February 2019) both appear functional and satisfactory.
- Plumbing
PEX supply piping in satisfactory condition; Kenmore 40-gallon natural gas water heater (manufactured 2003) appears functional with T&P relief valve and discharge pipe present.
- Home Inspection
Whole-home inspection of single-family property at 9938 Duke Dr found the home in generally good shape with no structural deficiencies; actionable items include window caulking, soffit/fascia repair, gutter cleaning, inoperable smoke detectors, mold in rear bedroom ceiling, and damage to middle bedroom ceiling.
- Windows
Vinyl windows are satisfactory overall but caulking is needed around windows as observed.
- Foundation
Slab-on-grade poured concrete foundation and wood-frame wall structure are both in satisfactory condition with no structural deficiencies observed.