Property records for 9835 Portage Drive, St. Louis, MO 63136

All 1 public upload record returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 1.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

Document (08/2026)

  • Electrical
  • Foundation
  • HVAC
  • Home Inspection
  • Pest
  • Plumbing
  • Roof
  • Sewer

On August 6, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 9835 Portage Drive, St. Louis, MO 63136.

Record date

Available findings

  • SewerWork status not resolved

    Sewer lateral lines are open and flowing; light scaling is present on the cast-iron portion but not enough to require cabling — no issues flagged.

  • PestWork status not resolved

    Visual WDI inspection of SFR/Attached Carport at 9835 Portage Drive found no visible evidence of wood destroying insects (termites, carpenter ants, carpenter bees, or reinfesting wood boring beetles); no treatment recommended.

  • ElectricalWork status not resolved

    100-amp Eaton service panel in basement is functional; 2-prong ungrounded outlets are present throughout; a functioning smoke detector should be installed in the basement near gas appliances.

  • FoundationWork status not resolved

    Poured concrete basement foundation is in satisfactory condition with no moisture detected and no deficiencies observed in basement walls or stairs; perimeter insulation is absent and adding insulation is suggested.

  • Home InspectionWork status not resolved

    Whole-home inspection of single-family property found the home generally in good condition with no structural issues; deficiencies noted include a cracked cast-iron sewer stack, inoperable sump pump with sparking outlet, cracked roof vent stack, and failed tub diverter valve.

  • HVACWork status not resolved

    Goodman central split system (manufactured 2015, 2.5-ton condenser) is functioning correctly but requires annual cleaning and servicing as it is over 10 years old.

  • PlumbingWork status not resolved

    A crack in the main sewer stack's cast-iron section is causing water to leak onto the basement floor; the sump pump is inoperable with a full sump well and a sparking outlet (both need replacement); the water heater expansion tank has a rusted fitting needing replacement; and the tub diverter valve has failed, requiring tub faucet replacement.

  • RoofWork status not resolved

    One metal roof exhaust vent stack is cracked, has been taped, and has lifted flashing — needs replacement; tree limbs are contacting the structure and should be cut back.