- Electrical · Inoperable smoke detector and ungrounded outlets found throughout home · 2026
- HVAC · Thermostat is broken and aging furnace needs cleaning and service · 2026
- Sewer · Root intrusion and pipe offset found, repairs likely needed · 2026
- Foundation · Basement wall crack was poorly repaired and needs proper fixing · 2026
- Roof · Aging roof shows wear and needs tree trimming and re-caulking · 2026
Ask this homePowered by Fresh House property intelligence®
Reading property memory…
RECORD SUMMARY
1 documented event
1 independent contributor
First recorded: Jun 2026
Most recent update: Jun 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
Home Inspection
Home Inspection Document
Inspected Jun 25, 2026 · uploaded Jun 29, 2026
Documented from uploaded report
Property Professional Uploaded
- Home InspectionWhole-home inspection of 1501 Golden Dr, Saint Louis, MO 63137 identified deficiencies across roofing, structure, HVAC, sewer lateral, electrical, and windows, with the home generally in good condition and no major structural issues.
- PestWood Destroying Insect inspection found no visible evidence of wood destroying insects; no action or treatment recommended; garage was inaccessible during inspection.
- SewerSewer camera inspection identified root intrusion at the connection between 4" cast iron and 6" clay pipe, and a large offset just past the clay connection (located and marked at approximately 10 feet depth under front yard bushes); referral to the sewer lateral program recommended for repairs.
- Roof3-tab shingled roof is approximately 10-15 years old and shows signs of wear; tree limbs in contact with roof should be trimmed, and the large metal vent stack requires re-caulking.
- FoundationA hairline crack on the west basement wall was repaired in a sloppy fashion and needs to be properly repaired via polyurethane foam crack injection.
- HVACThe HVAC thermostat is inoperable from the wall and needs repair; the Lennox gas furnace (manufactured 2006) needs to be cleaned and serviced annually, while the Goodman AC condenser (manufactured 2021) is functional.
- SewerA sewer lateral scope revealed an offset with a small disconnect requiring repair, with tree roots encroaching into the area; repair may be eligible for the city's sewer lateral repair program.
- PlumbingRheem 40-gallon natural gas water heater (manufactured 2021) is functioning properly; bathtub needs re-caulking; PEX supply pipes are satisfactory.
- ElectricalThe smoke detector in the basement is inoperable and needs replacement; 2-prong ungrounded outlets are present throughout the home.
- WindowsAll windows opened and closed correctly; however, one front-facing bedroom window appears to have a broken seal and requires repair or replacement.
Fresh House generated structured findings from a documented professional record.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.
PROPERTY COVERAGE
Home Inspection
✓ documentedRoof
✓ documentedPlumbing
✓ documentedSewer
✓ documentedFoundation
✓ documentedElectrical
✓ documentedHVAC
✓ documentedPest
✓ documentedWindows
✓ documentedMold
undocumentedRadon
undocumentedAppraisals
undocumented