Highlights selected from 1 documented record for this property.
- Electrical · Basement smoke detector is broken and needs replacement · 2026
- HVAC · Thermostat not working and older furnace needs servicing · 2026
- Sewer · Sewer line has root intrusion and offset needing repair · 2026
- Foundation · Basement wall crack needs proper polyurethane foam injection repair · 2026
- Roof · Aging roof shows wear and needs tree trimming and re-caulking · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 1501 Golden Drive, St. Louis, MO 63137, dated in June 2026.
Home Inspection Document
On June 25, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 6 other topics at 1501 Golden Drive, St. Louis, MO 63137.
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Sewer,
- Windows
- Home InspectionWhole-home inspection of 1501 Golden Dr, Saint Louis, MO 63137 identified deficiencies across roofing, structure, HVAC, sewer lateral, electrical, and windows, with the home generally in good condition and no major structural issues.
- PestWood Destroying Insect inspection found no visible evidence of wood destroying insects; no action or treatment recommended; garage was inaccessible during inspection.
- SewerSewer camera inspection identified root intrusion at the connection between 4" cast iron and 6" clay pipe, and a large offset just past the clay connection (located and marked at approximately 10 feet depth under front yard bushes); referral to the sewer lateral program recommended for repairs.
- PlumbingRheem 40-gallon natural gas water heater (manufactured 2021) is functioning properly; bathtub needs re-caulking; PEX supply pipes are satisfactory.
- ElectricalThe smoke detector in the basement is inoperable and needs replacement; 2-prong ungrounded outlets are present throughout the home.
- WindowsAll windows opened and closed correctly; however, one front-facing bedroom window appears to have a broken seal and requires repair or replacement.
- Roof3-tab shingled roof is approximately 10-15 years old and shows signs of wear; tree limbs in contact with roof should be trimmed, and the large metal vent stack requires re-caulking.
- FoundationA hairline crack on the west basement wall was repaired in a sloppy fashion and needs to be properly repaired via polyurethane foam crack injection.
- HVACThe HVAC thermostat is inoperable from the wall and needs repair; the Lennox gas furnace (manufactured 2006) needs to be cleaned and serviced annually, while the Goodman AC condenser (manufactured 2021) is functional.
- SewerA sewer lateral scope revealed an offset with a small disconnect requiring repair, with tree roots encroaching into the area; repair may be eligible for the city's sewer lateral repair program.