  • Electrical
    Electrical · Basement smoke detector is broken and needs replacement · 2026
  • HVAC
    HVAC · Thermostat not working and older furnace needs servicing · 2026
  • Sewer
    Sewer · Sewer line has root intrusion and offset needing repair · 2026
  • Foundation
    Foundation · Basement wall crack needs proper polyurethane foam injection repair · 2026
  • Roof
    Roof · Aging roof shows wear and needs tree trimming and re-caulking · 2026
Ask this homePowered by Fresh House property intelligence®
Reading property memory…

RECORD SUMMARY

1 documented event
Contributed by: 1 contributor
First documented event: Jun 2026
Latest documented event: Jun 2026
First added to Fresh House: Jun 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 1 documented record for 1501 Golden Drive, St. Louis, MO 63137, dated in June 2026.

Home Inspection

Home Inspection Document

Inspected Jun 25, 2026Uploaded Jun 29, 2026
Documented from uploaded report
Property Professional Uploaded

On June 25, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 6 other topics at 1501 Golden Drive, St. Louis, MO 63137.

Scope
  • Electrical,
  • Foundation,
  • HVAC,
  • Home Inspection,
  • Pest,
  • Plumbing,
  • Roof,
  • Sewer,
  • Windows
Contributor
worked on or inspected it
  • Home InspectionWhole-home inspection of 1501 Golden Dr, Saint Louis, MO 63137 identified deficiencies across roofing, structure, HVAC, sewer lateral, electrical, and windows, with the home generally in good condition and no major structural issues.
  • PestWood Destroying Insect inspection found no visible evidence of wood destroying insects; no action or treatment recommended; garage was inaccessible during inspection.
  • SewerSewer camera inspection identified root intrusion at the connection between 4" cast iron and 6" clay pipe, and a large offset just past the clay connection (located and marked at approximately 10 feet depth under front yard bushes); referral to the sewer lateral program recommended for repairs.

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this home.

PROPERTY COVERAGE

Home Inspection
✓ documented
Roof
✓ documented
Plumbing
✓ documented
Sewer
✓ documented
Foundation
✓ documented
Electrical
✓ documented
HVAC
✓ documented
Pest
✓ documented
Windows
✓ documented
Mold
undocumented
Radon
undocumented
Appraisals
undocumented

Nearby homes with documented history