- Electrical · Smoke detectors missing throughout home, GFCI outlets faulty · 2026
- HVAC · Vegetation is crowding and obstructing the AC condenser unit · 2026
- Sewer · Heavy tree root intrusion and sludge found in sewer lateral · 2026
- Foundation · Basement foundation is solid with no moisture or damage found · 2026
- Roof · Fallen tree limb damaged gutter and downspout needs reset · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 1212 Grenshaw Drive, St. Louis, MO 63137, dated in August 2026.
Home Inspection Document
On August 19, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 1212 Grenshaw Drive, St. Louis, MO 63137.
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Sewer
- Home InspectionWhole-home inspection of single-family property identified multiple deficiencies including end-of-life HVAC, sewer lateral root intrusion, damaged gutter, failed bathroom GFCI, reversed laundry GFCI wiring, loose basement handrail, and missing smoke detectors; no structural issues found.
- ElectricalCutler Hammer 100-amp panel is functional; smoke detectors are missing throughout the home, bathroom GFCI outlet is older and will not trip (needs replacement), and laundry GFCI outlet has hot and ground wires reversed; 2-prong ungrounded outlets are present.
- FoundationPoured concrete basement foundation is satisfactory with no moisture detected and no deficiencies observed in basement walls; loose handrail on basement stairs needs to be secured.
- HVACvegetation is crowding the AC condenser
- Plumbingcopper supply pipes and PVC waste pipes are satisfactory
- RoofArchitectural shingles estimated 5-10 years old and performing properly; a fallen tree limb damaged the gutter which needs replacement, and the front corner downspout needs reset as it is dumping rain wash onto the roof.
- SewerNo damage found to sewer lateral lines, but heavy tree root intrusion and sludge are present; hydroflushing recommended to maintain proper flow and prevent backups.
- SewerSewer lateral inspection found no structural damage to the lateral lines, but heavy tree root intrusion and sludge are present; hydroflushing is recommended to maintain proper flow and prevent backups.
- Pestno action or treatment recommended
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.