1890 Pyrenees Drive
Florissant, Missouri, 6303338.8038°N, 90.2861°W
1Event
1Contributor
Fresh House Property Summary
Generated from 1 documented record on this property page.
- HVAC · Furnace and AC are about 20 years old and need cleaning and service · 2023
- Electrical · 100-amp panel inspected and approved with no outlet defects found · 2023
- Foundation · Old basement wall repairs are cracking and show past moisture signs · 2023
- Plumbing · Massive leak under kitchen and main shutoff valve also leaking · 2023
- Roof · One to two shingles are lifted and tree limbs overhang the roof · 2023
Ask this homePowered by Fresh House property intelligence®
Reading property memory…
RECORD SUMMARY
1 documented event
1 independent contributor
First recorded: Apr 2026
Most recent update: Apr 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
DOCUMENTED
Home Inspection
Inspected Nov 16, 2023 · uploaded Apr 28, 2026
Documented from uploaded report
Property Professional Uploaded
Scope
ElectricalFoundationHVACHome InspectionPestPlumbingRoofWindows
Contributor
worked on or inspected it- Home InspectionWhole-home inspection of 1890 Pyrenees Dr, Florissant, MO found the home in generally good shape with no structural deficiencies; key concerns include a heavy plumbing leak below the kitchen, cracking basement wall repairs, and a 20-year-old HVAC system needing service.
- ElectricalMurray 100-amp service panel located in the basement is a newer panel approved by the City of Florissant (electrical inspection dated 5-3-19); overcurrent protection via breakers is satisfactory and no outlet defects were noted.
- PestNo termite or pest presence or damage was observed at the time of inspection.
- PlumbingA massive leak is present directly below the kitchen from a loose fitting in the supply lines; the main water shut off valve is also leaking at the handle and needs repair; the 40-gallon State natural gas water heater (manufactured 2020) appears functional.
- HVACBryant forced-air gas furnace (71,000 BTU, manufactured 2001) and Bryant 2.5-ton split-system condenser (manufactured 2001) are approximately 20 years old, need cleaning and servicing, but appear to be performing.
- RoofThree-tab shingled roof estimated 10–15 years old is in satisfactory condition; 1–2 shingles are lifted and need to be sealed down, and tree limbs overhanging the roof should be cut back as a large limb has dropped onto the power lines.
- FoundationPrevious repairs to the basement wall are beginning to crack; inspector recommends tearing out old fill and sealing the crack with epoxy injection; no active moisture intrusion was observed but signs of previous moisture were present.
- WindowsExterior windows consist of wood, vinyl, and steel-framed basement windows, all observed in satisfactory condition.
Fresh House generated structured findings from a documented professional record.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.
PROPERTY COVERAGE
Home Inspection
✓ documentedRoof
✓ documentedPlumbing
✓ documentedFoundation
✓ documentedElectrical
✓ documentedHVAC
✓ documentedPest
✓ documentedWindows
✓ documentedSewer
undocumentedMold
undocumentedRadon
undocumentedAppraisals
undocumented