Hi, I'm 2054 Krause Hill Place. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
← MAPSOURCE-BACKED RECORDS
2054 Krause Hill Place
Florissant, MO 6303138.7967°N, 90.3754°W
1Event
Contributed by:1 contributor
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- Electrical · Missing GFCI outlets and reversed wiring found in several locations · 2026
- HVAC · Aging 2011 heating and cooling system needs annual servicing · 2026
- Foundation · Basement floor and exterior foundation cracks need sealing · 2026
- Windows · Basement window trim blocks opening — a safety concern · 2026
- Plumbing · Laundry sink drain improperly connected and main shutoff corroded · 2026
Ask this homePowered by Fresh House property intelligence®
ASK ME ABOUT
RECORD SUMMARY
1 documented event
Contributed by: 1 contributor
First documented event: Aug 2026
Latest documented event: Aug 2026
First added to Fresh House: Aug 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
This page contains 1 documented record for 2054 Krause Hill Place, Florissant, MO 63031, dated in August 2026.
Home Inspection
Home Inspection Document
Inspected Aug 13, 2026Uploaded Aug 17, 20264 files
Documented from uploaded report
Property Professional Uploaded
By
Greensmith Home Inspection llcdocumented Electrical, Foundation, HVAC, and 7 other topics at 2054 Krause Hill Place, Florissant, MO 63031.
Scope
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Radon,
- Roof,
- Sewer,
- Windows
Contributor
worked on or inspected it- Home InspectionWhole-home inspection of single-family property found home in generally good condition with no structural issues; deficiencies noted across electrical, HVAC, plumbing, windows, foundation, and pest categories.
- Electrical200-amp Crouse-Hinds panel (aged but performing) with multiple missing GFCI outlets (kitchen, laundry, rear exterior), one inoperable patio outlet, one basement outlet with hot and neutral wires reversed, and two-prong ungrounded outlets present throughout.
- FoundationUnfinished basement floor has cracks that should be sealed with epoxy; exterior foundation crack should be sealed with urethane caulk; no moisture intrusion observed in basement.
- HVACGoodman central split system (furnace and 3-ton condenser) manufactured in 2011 is functioning properly but requires annual cleaning and servicing; vegetation crowding the AC condenser must be removed.
- PestOlder termite damage observed on a small section of wooden fence in the backyard; no active termite activity found on the rest of the structure; treatment or fence removal recommended.
- PlumbingBasement laundry sink drains directly into open floor drain (needs proper P-trap and connection to sewer stack); Rheem 40-gallon natural gas water heater (manufactured 2017) functioning properly; main water shutoff needs corrosion removed.
- RoofArchitectural shingle roof estimated 2-5 years old, installed correctly and in satisfactory condition; gable design with metal flashings, aluminum soffit/fascia, and metal gutters all satisfactory.
- WindowsTwo windows (one in living room, one in master bedroom) have broken seals and need replacement; bedroom window plastic grille is broken and taped; basement window trim cut too close preventing windows from opening; a safety concern.
- SewerSewer lateral lines are open and flowing with no obstructions and no damages observed; lateral lines are PVC from the main stack to the city tie-in.
- PestVisual inspection found older termite damage on the wood fence; no live insects observed; recommendation to spray the affected area with a borate-based solution or remove the damaged fence.
- Radonaverage result was 3.0 pCi/L over 91 hourly intervals, with a minimum of 1.3 pCi/L and maximum of 4.9 pCi/L
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.
PROPERTY COVERAGE
Home Inspection
✓ documentedRoof
✓ documentedPlumbing
✓ documentedSewer
✓ documentedFoundation
✓ documentedElectrical
✓ documentedHVAC
✓ documentedPest
✓ documentedRadon
✓ documentedWindows
✓ documentedMold
undocumentedAppraisals
undocumented