Fresh House Property Summary
Generated from 1 documented record on this property page.
- HVAC · Furnace CO levels failed safety test — urgent professional repair needed · 2026
- Electrical · Outdated GFCI outlets won't reset and one outlet has open ground wire · 2026
- Foundation · Basement foundation is solid; minor floor cracks should be sealed · 2026
- Sewer · Main sewer line is open, flowing, and in good condition · 2026
- Plumbing · Leaky laundry drain pipe and broken tub diverter need repair · 2026
Ask this homePowered by Fresh House property intelligence®
Reading property memory…
RECORD SUMMARY
1 documented event
1 independent contributor
First recorded: Jun 2026
Most recent update: Jun 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
HVAC
HVAC Document
Inspected Jun 16, 2026 · uploaded Jun 22, 2026
Documented from uploaded report
Property Professional Uploaded
- Home InspectionWhole-home inspection of 416 Harvest Hill Ct, Ballwin, MO 63021 identified multiple deficiencies including elevated CO levels from the HVAC system, outdated GFCI outlets, a leaky laundry drain pipe, a bad tub diverter, dry-rotted exterior door trim, and a dirty gas fireplace requiring professional cleaning.
- RadonRadon test conducted in the basement from June 16–18, 2026 using a RadStar RS300 monitor; average radon level measured at 0.5 pCi/L (maximum 1.5 pCi/L, minimum 0.1 pCi/L), which is below the EPA action level of 4.0 pCi/L.
- PestWood Destroying Insect inspection of SFR/Attached Garage at 416 Harvest Hill Court, Ballwin, MO: no visible evidence of wood destroying insects was observed; no action or treatment recommended.
- SewerCamera inspection of main sewer line from 4-inch PVC to 6-inch PVC to the MSD tie-in; line is open and flowing and looks good.
- HVACCombustion analyzer test failed with CO levels higher than industry standards on the 2021 Emerald furnace; qualified HVAC contractor evaluation and readjustment recommended; fireplace gas logs are dirty with carbon buildup and need professional cleaning.
- PlumbingLeaky drain pipe found at the basement laundry sink; hallway bathroom tub faucet diverter is likely bad (approximately 50% of water dumps from tub spout in shower mode) and faucet handle is not attached; water heater (AO Smith, 50-gal, natural gas, Mfgd 2021) is functioning properly.
- ElectricalGFCI outlets in both the master bathroom and hallway bathroom are outdated and will not reset, requiring repair or replacement; one basement outlet has an open ground wire needing repair; master bathroom exhaust fan is extremely loud with a likely failing bearing and should be replaced.
- RoofArchitectural shingle roof estimated 8–10 years old is installed correctly and in satisfactory condition; skylight repairs appear effective; porch is missing a trim piece of fascia with exposed wood present.
- FoundationPoured concrete basement foundation is in satisfactory condition with no structural issues observed; common cracks in the unfinished basement floor are noted and should be sealed with urethane caulk.
- WindowsVinyl windows throughout are in satisfactory condition; caulking around window interiors is recommended as needed.
- HVACGas appliance inspection identified: furnace combustion analyzer test failed with CO levels above industry standards and abnormal blower/inducer motor noise; flue too close to combustible material; water heater and furnace gas shut-off valves not hand-turnable; copper gas lines not marked; gas shut-off valve not labeled; stove middle burner did not light completely; gas log dirty with carbon buildup; condenser not properly secured to rack and condenser fins dirty — qualified HVAC contractor evaluations and repairs recommended for all items.
Fresh House generated structured findings from a documented professional record.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.
PROPERTY COVERAGE
Home Inspection
✓ documentedRoof
✓ documentedPlumbing
✓ documentedSewer
✓ documentedFoundation
✓ documentedElectrical
✓ documentedHVAC
✓ documentedPest
✓ documentedRadon
✓ documentedWindows
✓ documentedMold
undocumentedAppraisals
undocumented