- Electrical · Tree limbs pushing power lines dangerously low, need trimming · 2026
- HVAC · Air conditioner not cooling properly and may be low on refrigerant · 2026
- Sewer · Sewer line has a suspected collapse and complete blockage · 2026
- Foundation · Basement wall crack found and needs to be sealed · 2026
- Plumbing · Main water shutoff handle is broken and needs replacement · 2026
Ask this homePowered by Fresh House property intelligence®
ASK ME ABOUT
RECORD SUMMARY
1 documented event
Contributed by: 1 contributor
First documented event: Jun 2026
Latest documented event: Jun 2026
First added to Fresh House: Jun 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
This page contains 1 documented record for 83 Grand Circle Drive, Maryland Heights, MO 63043, dated in June 2026.
Home Inspection
Home Inspection Document
Inspected Jun 17, 2026Uploaded Jun 24, 20265 files
Documented from uploaded report
Property Professional Uploaded
By
Greensmith Home Inspection llcdocumented Electrical, Foundation, HVAC, and 7 other topics at 83 Grand Circle Drive, Maryland Heights, MO 63043.
Scope
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Radon,
- Roof,
- Sewer,
- Windows
Contributor
worked on or inspected it- Home InspectionWhole-home inspection of 83 Grand Circle Dr, Maryland Heights, MO 63043 identified multiple deficiencies including an inoperable attic fan, power line hazard, sewer blockage, broken water shutoff handle, failed laundry GFCI outlet, and a basement window locking issue; home is generally in good condition with no structural issues.
- RadonRadon test conducted in basement from June 17. average radon level measured at 0.5 pCi/L, well below the EPA action level of 4.0 pCi/L
- PestWood Destroying Insect inspection of SFR/Attached Garage found no visible evidence of wood destroying insects; no action or treatment recommended.
- SewerSewer camera inspection of main line (3-inch PVC to 4-inch cast iron to 6-inch clay tile to yard vent) revealed the line holding water and a blockage the camera could not pass, with a suspected break in the clay tile located and marked with green paint approximately 5 ft. deep in the back yard; report recommended to be submitted to the lateral sewer program for repair and reinspection.
- ElectricalTree limbs are pushing overhead power lines down to approximately 9 feet from the ground and need to be cut back by Ameren; Siemens 200-amp service panel is newer and appears functional.
- FoundationPoured concrete basement foundation is in satisfactory condition with no moisture intrusion detected; one basement wall crack needs to be sealed with urethane.
- HVACAttic fan is inoperable from the wall switch and needs repaired or replaced; Goodman forced-air furnace (Mfgd 2024, 80,000 BTU) and Ameristar 2.5-ton condenser (Mfgd 2018) are functioning but require cleaning, servicing, and a missing HVAC filter needs to be replaced.
- PestVisual inspection of the site revealed no termite or pest presence or damage observed.
- PlumbingBroken handle on the main water shutoff valve in the basement needs replacement; Bradford White 40-gallon electric water heater (Mfgd 2025) is functioning properly; basement laundry GFCI outlet is older, will not reset, and needs replaced.
- RoofArchitectural shingle roof estimated 10 years old is installed correctly and in satisfactory condition; metal gutters contain leaves and need cleaning.
- SewerSewer lateral videoscope revealed a complete blockage at the sinkhole in the backyard; the line is suspected to be collapsed and St. Louis MSD Sewer is recommended to inspect, as it may be covered under the city's program.
- WindowsNewer double-hung vinyl windows open and close properly; however, one basement window will not lock and needs an adjustment to the locking mechanism.
- HVACGas appliance inspection of 2024 80k BTU 80% efficiency furnace (passed combustion analysis, dirty condition), 2018 2.5-ton condenser (dirty, not cooling properly, refrigerant charge appears low), 2017 3-ton A-coil (properly draining), and ductwork (serviceable); gas lines hold pressure with no major concerns noted.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.
PROPERTY COVERAGE
Home Inspection
✓ documentedRoof
✓ documentedPlumbing
✓ documentedSewer
✓ documentedFoundation
✓ documentedElectrical
✓ documentedHVAC
✓ documentedPest
✓ documentedRadon
✓ documentedWindows
✓ documentedMold
undocumentedAppraisals
undocumented