949 Clearfield Drive
Across 4 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed

Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 4 documented records
Fresh House Property Summary
Highlights selected from 4 documented records for this property.
- HVAC · Furnace condensation line disconnected, causing moisture buildup · 2023
- Foundation · Crack found in foundation corner and soft kitchen floor spot · 2023
- Roof · Aging roof has heavy hail damage and possible leak · 2023
- Plumbing · Old ejector pump removed and new pump installed, no leaks · 2025
- Plumbing · Burst pipe in basement repaired with copper plumbing · 2025
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 4 documented records for 949 Clearfield Drive, Ferguson, MO 63135, dated from March 2023 through April 2025. The amount summary includes $2,000.80 with completion status not stated; appraisal values and permit-declared valuations are excluded.
Plumbing Ejector Pump Installation — New 1/3 HP ejector pump
- Plumbing
- $850PlumbingRemoved old pump and installed new 1/3 HP ejector pump with assembly, preventive water backflow, pump operational with no leaks; 30-day warranty.
Documented warranty30 DaysFrom recordView details
- 30 Days Warranty
Coverage based on the record. Start date, ownership or occupancy, service territory, product or ordered options, transferability, and exclusions may affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Plumbing Pipe Burst Repair — Water pipe burst, 1/4" copper replaced
- Plumbing
- $650PlumbingInstalled all 1/4" copper plumbing water pipe in basement to repair burst pipe; no leaks; 30-day warranty; paid in full.
Documented warranty30 DaysFrom recordView details
- 30 Days Warranty
Coverage based on the record. Start date, ownership or occupancy, service territory, product or ordered options, transferability, and exclusions may affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Plumbing Drain Repair Invoice — tub waste arm installed into iron
- Plumbing
- $501PlumbingInstalled tub waste arm and lead into iron stack with no leaks; 30-day warranty provided. Additional recommendation to replace tub drain.
Documented warranty30 DaysFrom recordView details
- 30 Days Warranty
Coverage based on the record. Start date, ownership or occupancy, service territory, product or ordered options, transferability, and exclusions may affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Home Inspection
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof
- Home InspectionWhole-home inspection of 949 Clearfield Dr found the home in generally good shape with no structural deficiencies; notable issues include damaged front porch railing, rear fence destroyed by neighbor's tree, vegetation contacting structure, inoperative dishwasher, and missing kitchen exhaust fan over gas range.
- Electrical100-amp Square D service panel with breakers in satisfactory condition; smoke detectors are 9-volt battery type only.
- FoundationSmall crack observed in poured concrete foundation at front corner of home; urethane caulk repair recommended; soft spot also noted in kitchen floor next to rear exterior door requiring repair.
- HVACCondensation line is disconnected and laying next to the Goodman furnace (2015), causing moisture to run from the furnace when in use; Ruud 3-ton condenser (2016) appears functional.
- PestNo active termite damage or presence observed on the structure, but older termite damage is present on wood landscaping timbers; spraying for termites/wood-destroying insects every 3; 5 years is recommended.
- PlumbingRuud water heater manufactured 2002 appears functional with 40-gallon natural gas capacity and T&P relief valve present; copper supply pipes and sump pump are satisfactory.
- Roof3-tab shingle roof estimated 25 years old with heavy hail damage and replacement suggested in the near future; guttering on rear half of house has been pulled down and needs reset; ceiling stains in rear bedroom directly below satellite dishes indicate possible roof leak requiring repair.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.