4615 Newport Avenue

Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- Electrical · Smoke detectors broken or missing throughout the home · 2026
- Sewer · Complete sewer blockage found — needs flushing before full inspection · 2026
- Foundation · Basement stone walls have worn mortar allowing moisture in · 2026
- Roof · Roof is about 10 years old with patching and missing fascia sections · 2026
- Plumbing · Water heater untestable due to winterization; tub faucet missing · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 4615 Newport Avenue, St. Louis, MO 63116, dated in July 2026.
Home Inspection Document
On July 28, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 6 other topics at 4615 Newport Avenue, St. Louis, MO 63116.
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Sewer,
- Windows
- Home InspectionWhole-home inspection of single-family property identified 11 deficiencies across exterior, roofing, structure, electrical, HVAC, plumbing, sewer, windows, and interior systems; no structural issues found.
- SewerSewer lateral video scope performed; compacted grease and feces have formed a full blockage 6' below the main stack access — lines need hydroflushed to remove debris, then re-camera'd behind the blockage.
- PestWood Destroying Insect inspection of SFR at 4615 Newport Avenue, St. Louis, MO 63116: no visible evidence of wood destroying insects observed; no action or treatment recommended.
- Electrical200-amp Square D service panel in basement appears functional; smoke detectors are broken/missing and functional units need to be installed throughout the home.
- FoundationStone basement walls have worn mortar that needs sealing to prevent moisture intrusion; moisture condition is damp and Drylok or similar coating is recommended.
- HVACPayne central split system (2-ton A/C and forced-air furnace, manufactured 2022) appears functional; HVAC filter is missing and needs replacement.
- PlumbingRheem 40-gallon electric water heater (manufactured 2023) could not be tested due to winterization; missing tub faucet in main-floor bathroom needs replacement; PEX supply pipes satisfactory.
- RoofArchitectural shingle roof estimated 10 years old is satisfactory with patching present; missing aluminum fascia sections need replacement.
- SewerSewer lateral video scope revealed a complete blockage of grease and fecal matter that requires hydroflushing before the remainder of the sewer line can be inspected.
- WindowsTwo broken window panes identified — one in the basement and one in the attached rear room — both need replacement.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,