Home inspector

Greensmith Home Inspection LLC
Home inspection company in St. Louis, MO
AREAS OF EXPERTISE
4 servicesProfile-listed services
Full service & record summaryPROPERTY RECORDS
What this professional has documented.
Structured findings below are extracted from the documented professional records shown on this page.
10 property records shown.
Whole-home inspection, 333 Lancashire Road, St. Louis, MO 63137
Greensmith Home Inspection LLC documented home inspection work at 333 Lancashire Road, St. Louis, MO 63137 on March 10, 2023. Bedroom smoke detectors are present but not functioning.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of 333 Lancashire Rd, St Louis, MO 63137 identified six actionable items including roof deficiencies, non-functioning smoke detectors, slow drains, missing kitchen exhaust fan, and a missing exterior siding panel; no structural deficiencies were observed.
- ElectricalBedroom smoke detectors are present but not functioning; inspector recommends installing functioning smoke detectors throughout the house; 100-amp General Electric panel with breakers is satisfactory.
- FoundationPoured concrete foundation with basement access inspected; no moisture detected, no structural deficiencies observed, and basement walls are satisfactory; perimeter insulation is not visible and adding insulation is suggested.
- HVACGoodman gas forced-air furnace (manufactured 2005) and American Standard 2-ton split-system AC condenser (manufactured 2004) are both over 10 years old and should be checked, cleaned, and serviced yearly; kitchen exhaust fan is not present as the previous wall fan was removed and paneled over.
- PlumbingBathroom sink and bathtub were very slow to drain and drain lines likely need to be cleared; water heater is a State 40-gallon natural gas unit manufactured in 2022 and is satisfactory; copper supply pipes and PVC waste pipes are satisfactory.
- RoofShingled roof is estimated 25 years old with two damaged shingles, previous patching, and a large tarp present; per seller's agent the roof is in process of being replaced; tree limbs are hanging over and contacting the roof structure.
- WindowsVinyl and steel-framed basement windows inspected and found to be in satisfactory condition with no deficiencies noted.
333 Lancashire Road
St. Louis, Missouri
Whole-home inspection, 10651 Dunkeld Circle, St. Louis, MO 63137
Greensmith Home Inspection LLC documented home inspection work at 10651 Dunkeld Circle, St. Louis, MO 63137 on March 10, 2023. 100-amp overhead electrical service with Crouse-Hinds panel located in basement.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of 10651 Dunkeld Cir, St Louis, MO 63137 identified multiple deficiencies including a dirty 1992 Lennox furnace needing service, inoperable oven and dishwasher, termite damage on exterior wood door, missing front porch handrails, damaged front storm door, and a crack in the dining room ceiling; no structural deficiencies were observed.
- Electrical100-amp overhead electrical service with Crouse-Hinds panel located in basement; breakers and smoke detectors tested satisfactory with no deficiencies noted.
- FoundationPoured concrete basement foundation is in satisfactory condition with no structural deficiencies, no moisture detected, and no deficiencies observed on basement walls; perimeter insulation is absent and adding insulation is suggested.
- HVACLennox furnace manufactured in 1992 is dirty and needs to be cleaned and serviced by an HVAC technician; Kelvinator 2-ton split system condenser (manufactured 2004) appears functional but is over 10 years old and should be serviced yearly.
- PestOlder termite damage is present on the exterior of a wood door; no damage was observed anywhere else on the structure, and treatment is recommended unless the seller can prove prior treatment.
- PlumbingCopper supply pipes and PVC waste pipes are in satisfactory condition; Rheem 40-gallon natural gas water heater manufactured in 2022 appears functional with T&P relief valve present.
- Roof3-tab shingle roof estimated 10 years old is in satisfactory condition; one asphalt shingle has lifted and needs to be sealed back down, and gutters need leaves and debris removed.
- WindowsExterior windows (wood, aluminum, and steel-framed basement windows) are in satisfactory condition with no deficiencies noted.
- UnclassifiedFrigidaire range oven is inoperable and needs repair per occupant; GE dishwasher is inoperable per occupant; damaged front storm door needs repair; missing handrails on front porch need replacement; loose exterior faucet at front porch needs to be secured; crack in dining room ceiling needs to be sealed.
10651 Dunkeld Circle
St. Louis, Missouri
Whole-home inspection, 10333 Lilac Avenue, St. Louis, MO 63137
Greensmith Home Inspection LLC documented home inspection work at 10333 Lilac Avenue, St. Louis, MO 63137 on March 10, 2023. Smoke detectors are inoperable and need to be replaced with functioning smoke detectors.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property at 10333 Lilac Ave, St Louis, MO found the home in generally good shape with no structural deficiencies; five items flagged for repair or attention across exterior, roof, electrical, and plumbing systems.
- ElectricalSmoke detectors are inoperable and need to be replaced with functioning smoke detectors; Siemens 100-amp service panel with breakers appears functional.
- FoundationPoured concrete basement foundation shows no moisture detected and no deficiencies observed in walls; perimeter insulation is not visible and adding insulation is suggested.
- HVACLennox forced-air gas furnace (manufactured 2005) and Lennox 2-ton split-system condenser (manufactured 1998) both appear functional; furnace is over 10 years old and should be checked, cleaned, and serviced yearly by a licensed contractor.
- PlumbingLoose vanity sink faucet in bathroom needs to be secured; kitchen sink water pressure is very low, likely due to a clogged filter screen in the faucet; Ruud 38-gallon natural gas water heater (manufactured 2005) appears functional.
- RoofShingled roof is estimated 10 years old with patching/repairs present; one shingle has come loose and needs to be reattached.
- UnclassifiedExterior covering (lap wood siding and asbestos tiles) requires repair or replacement of damaged tiles, and wood siding at the front of the home needs to be scraped and painted.
10333 Lilac Avenue
St. Louis, Missouri
Whole-home inspection, 10254 Valley Drive, St. Louis, MO 63137
Greensmith Home Inspection LLC documented home inspection work at 10254 Valley Drive, St. Louis, MO 63137 on March 10, 2023. Multiple electrical deficiencies noted: GFI outlet at carport is inoperable.
Some source files are restricted or not yet available; only cleared records are shown.
- ElectricalMultiple electrical deficiencies noted: GFI outlet at carport is inoperable; bathroom GFI outlet will not reset and needs replacement; kitchen GFI outlet has hot and ground wires reversed and needs rewiring; electrical outlets near the utility area are inoperable despite breakers being on; smoke detectors are missing throughout the home including near basement gas appliances.
- FoundationPoured concrete foundation with basement access inspected; no moisture detected, no structural deficiencies observed, and basement walls and floor rated satisfactory.
- HVACCentral split system with DuCane forced-air gas furnace (manufactured 2021) and Coleman 2-ton electric AC condenser (manufactured 2022) both appear functional and rated satisfactory; kitchen exhaust fan for gas range is absent and installation is recommended.
- PestNo termite damage or presence was observed; termite treatment appears to have been previously performed.
- PlumbingCopper supply pipes and PVC waste pipes are satisfactory; General Electric 40-gallon natural gas water heater manufactured in 2007 appears functional but is approximately 16 years old.
- RoofRoof covering is 3-tab shingle and roll roofing estimated at 10 years old and rated satisfactory; ceiling damage in the middle bedroom is attributed to rain water leaking in during hard rains, indicating a potential roof leak; no gutters or downspouts are present.
- WindowsExterior windows include vinyl, aluminum, and steel-framed basement windows, all rated satisfactory with no deficiencies noted.
- UnclassifiedExterior trim damage on front corners of home and deteriorated hardboard siding over the front porch require repair.
10254 Valley Drive
St. Louis, MO
Whole-home inspection, 8440 North Broadway, St. Louis, MO 63147
Greensmith Home Inspection LLC documented home inspection work at 8440 North Broadway, St. Louis, MO 63147 on February 21, 2023. Exterior electrical weatherhead on building 8444 has melted with exposed wires present requiring Ameren power company to secure the electric meter mast.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-building inspection of 9-unit multi-family property at 8440 N Broadway (Bldg 8444) identified multiple deficiencies including electrical hazards, mold, foundation cracks, aged roof, broken windows, and HVAC units in need of servicing.
- ElectricalExterior electrical weatherhead on building 8444 has melted with exposed wires present requiring Ameren power company to secure the electric meter mast; smoke detectors are missing throughout the building and need replacement.
- FoundationCracks in the exterior foundation require epoxy injection repairs; basement walls show signs of flooding and water marks and need repair; subfloor in building 8444 is damaged, appearing to be from water damage on the west side of the basement.
- HVACMost all AC compressors are Goodman 2.5-ton units manufactured 2001; 2004, are very dirty, and need to be cleaned and serviced by an HVAC technician.
- MoldSigns of flooding and water marks in basement walls have turned to black mold; all mold must be removed and wall cracks behind finished sheetrock sealed to prevent future moisture intrusion.
- PlumbingWater heaters across units are various brands and ages (GE 2005, Whirlpool 2004, American 2002, Rheem 2015/2016/2018, Hotpoint 2005, State 2011) and were documented during inspection.
- RoofShingled roof is estimated 20 years old and has been patched but will likely need replacement soon; damaged soffit on west corners of roof needs repair; missing cap for roof exhaust vent pipe needs replacement.
- WindowsThree broken window panes in building 8444 need to be replaced.

8440 North Broadway
St. Louis, Missouri
Whole-home inspection, 8440 North Broadway, St. Louis, MO 63147
Greensmith Home Inspection LLC documented home inspection work at 8440 North Broadway, St. Louis, MO 63147 on February 21, 2023. All nine units have 100-amp service panels located in the basement with breaker-type overcurrent devices.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-building inspection of a 9-unit apartment building found the structure to be structurally sound but identified multiple defects across roofing, exterior, HVAC, plumbing, electrical, foundation, windows, and interior systems requiring repair.
- ElectricalAll nine units have 100-amp service panels located in the basement with breaker-type overcurrent devices; no main disconnect location was present in any unit.
- FoundationCracks are present in the basement floor at the basement wall allowing moisture intrusion; inspector recommends sealing all wall and floor cracks and coating with Drylok or similar waterproofing product.
- HVACMost units contain Goodman gas forced-air furnaces manufactured 2001; 2005 (Unit 4 and Unit 7 have Whirlpool, mfgd 2000); all units are dirty and need to be cleaned and serviced by an HVAC technician.
- PestNo active termite presence was observed to the structure, but older termite damage was found on wood landscape timbers; inspector recommends spraying for termites/pest wood-destroying insects every 3; 5 years.
- PlumbingBathroom sink in Unit 2 has no hot water; the water heater for Unit 3 (Envirotemp, mfgd 2016) has excessive rust due to a small leak in the supply pipe that needs repair; sheetrock wall damage around bedroom windows from previous water leaks was also noted in Units 6 and 9.
- RoofShingled roof is estimated 20 years old and has been patched extensively; tree limbs overhang the roof, a gutter downspout on the south side is loose, and missing soffit and aluminum fascia on the west eave expose wood.
- WindowsTwo broken window panes in the 8442 building require replacement, and caulking is needed around most all exterior windows.

8440 North Broadway
St. Louis, Missouri
Whole-home inspection, 6809 Saint Olaf Drive, Berkeley, MO 63134
Greensmith Home Inspection LLC documented home inspection work at 6809 Saint Olaf Drive, Berkeley, MO 63134 on December 13, 2022. Tree limbs are pushing on overhead power lines.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property identified active roof leaks, HVAC ductwork issues, electrical deficiencies, and interior ceiling damage requiring repair before occupancy.
- ElectricalTree limbs are pushing on overhead power lines; one living room outlet has no power and needs repair or replacement; ungrounded two-prong outlets are present throughout the home.
- FoundationSlab-on-grade foundation with concrete block material and wood frame wall structure observed in satisfactory condition with no structural deficiencies noted.
- HVACHVAC flexible ductwork is twisted and does not heat or cool evenly per occupant; furnace filter is missing; AC compressor (International Comfort, Mfgd 2018) is functional but dirty and needs cleaning.
- PlumbingPVC supply pipes are satisfactory; Rheem 40-gallon electric water heater (Mfgd 2018) is functional with T&P relief valve present, but lacks a fuel disconnect.
- RoofExtensive damage to 3-tab shingled roof (estimated 15 years old) with tarpaper exposed, tattered roof tarp in place, active roof leaks present, and gutters clogged with leaves and debris.
- WindowsExterior windows (wood, vinyl, aluminum) and interior windows (double hung, fixed) are in satisfactory condition with no defects observed.
6809 Saint Olaf Drive
Berkeley, MO
Whole-home inspection, 1009 Northdale Avenue, St. Louis, MO 63138
Greensmith Home Inspection LLC documented home inspection work at 1009 Northdale Avenue, St. Louis, MO 63138 on July 25, 2022. Missing smoke detectors need replacement, tree limbs are pushing on overhead power lines (contact Ameren), GFCI outlet absent in laundry area, and ungrounded two-prong outlets are present throughout the home.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property identified multiple deficiencies across site, exterior, roofing, structure, electrical, HVAC, plumbing, and interior systems, including loose deck planks, missing/damaged fencing, foundation cracks, moisture intrusion, and various repair items.
- ElectricalMissing smoke detectors need replacement, tree limbs are pushing on overhead power lines (contact Ameren), GFCI outlet absent in laundry area, and ungrounded two-prong outlets are present throughout the home.
- FoundationCracks observed in block foundation at front corner of home require sealing, and mortar cracks along SW corner of basement show active moisture intrusion tracking to where the wall meets the floor.
- HVACHVAC system appears functional but furnace (approx. 7 years old, Rheem 2015) and AC compressor (approx. 16 years old, American Standard 2006) both need cleaning and servicing by an HVAC technician; bathroom ventilator is inoperable and needs repair.
- PestTermite damage observed to wood fence; no termite damage or active presence was observed to the structure, but annual treatment for termites and wood-destroying insects is recommended.
- PlumbingToilet is loose at the base and runs for an extended time; needs to be secured and valve flap adjusted; water heater (Envirotemp, 40 gal, natural gas, manufactured 2009) is aging and should be monitored.
- RoofMissing roof shingle on front of home, lifted shingles need pressed and sealed to prevent moisture intrusion, trees contacting and hanging over roof, and damaged fascia board next to chimney need to be addressed.
- WindowsTwo windows have broken seals and need repair or replacement, one window has busted trim requiring repair, and several windows will not completely lock and need locking mechanisms adjusted.

1009 Northdale Avenue
St. Louis, MO
Whole-home inspection, 8820 Cozens Avenue, Jennings, MO 63136
Greensmith Home Inspection LLC documented home inspection work at 8820 Cozens Avenue, Jennings, MO 63136 on July 21, 2022. Older knob and tube wiring with taped joints is in use throughout the house.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of 8820 Cozens Ave., St. Louis, MO identified multiple deficiencies across electrical, plumbing, sewer, foundation, mold, HVAC, and interior systems requiring repair or further evaluation prior to occupancy.
- ElectricalOlder knob and tube wiring with taped joints is in use throughout the house; smoke detectors are not present; a weatherproof cover is missing from the exterior outlet on the east side; two-prong ungrounded outlets are in use; and tree limbs are pushing on overhead power lines.
- FoundationCracks are present in the concrete block foundation that have been repaired in a sloppy fashion; loose caulk should be removed and cracks properly sealed with urethane caulk.
- HVACThe Lennox central split system furnace and AC compressor (estimated 5 years old) appear functional but are dirty and need to be cleaned and serviced by a licensed HVAC technician.
- MoldMold presence was observed in the northeast corner room of the basement, likely resulting from poorly repaired cracks in the block foundation; mold needs to be removed and all cracks completely sealed.
- PlumbingExterior faucet at rear corner is inoperable, and the clothes washing machine discharges waste water into an open floor drain rather than a proper drain connection cut into the nearby sewer stack.
- RoofThe 3-tab shingle roof (estimated 15 years old) is in satisfactory condition overall; a loose gutter on the front corner of the home needs to be secured.
- SewerSewer lateral scope revealed an offset where two pipe sections have come loose with one section sitting several inches higher, and a foreign item is lodged at the offset; the intersection needs to be excavated and repaired to prevent future backups.

8820 Cozens Avenue
Jennings, MO
Whole-home inspection, 8936 Gateland Avenue, Jennings, MO 63136
Greensmith Home Inspection LLC documented home inspection work at 8936 Gateland Avenue, Jennings, MO 63136 on January 26, 2022. GFI outlet in basement bathroom has an open ground wire and needs rewiring.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of a single-family property found the home in generally good shape with no structural deficiencies, but identified multiple items requiring repair across roofing, electrical, sewer, foundation, HVAC, windows, and exterior systems.
- ElectricalGFI outlet in basement bathroom has an open ground wire and needs rewiring; GFI outlet in main floor bathroom has hot and neutral wires reversed and needs rewiring; two-prong ungrounded outlets are present throughout the home; smoke detectors are not operational.
- FoundationCracks present in basement bathroom wall requiring urethane caulk to seal, and broken corners on exterior foundation recommended to be sealed; no moisture intrusion was detected.
- HVACVegetation is growing over the AC compressor and contacting the roof and needs to be cut back; the missing cover for the clothes dryer exhaust vent needs replacement; Coleman forced-air furnace (2016, 80,000 BTU) and Coleman 3-ton split-system AC unit were otherwise found satisfactory.
- PlumbingCopper supply pipes and PVC waste pipes are satisfactory; Rheem 40-gallon natural gas water heater (manufactured 2019) and sealed-crock sump pump are in satisfactory condition.
- RoofShingled roof (estimated 10 years old) shows signs of wear with 2-3 torn shingles needing replacement, gutters clogged with leaves and debris requiring cleaning, and older wood at upper-level fascia needing replacement.
- SewerSewer lateral scope was performed and revealed a crack at the top of the pipe along with scaling and buildup; a video report was noted to follow.
- WindowsBasement bedroom window is newer but will not open and appears to be jammed; caulking around the interior of windows is recommended for energy efficiency.
8936 Gateland Avenue
Jennings, Missouri
Greensmith Home Inspection LLC is a home inspection company based in St. Louis, Missouri. As of November 22, 2026, Fresh House holds 110 documented inspection records for Greensmith Home Inspection LLC at 106 properties in 23 municipalities, dated January 2022 to November 2026. The records contain findings from inspection reports. Original inspection reports are not shown publicly on this profile. This page carries no ratings, no reviews and no paid placement.
What the Fresh House records show
| Finding | Count | Sentence |
|---|---|---|
| HVAC findings | 100 records | 100 published records for Greensmith Home Inspection LLC include HVAC findings. |
| Electrical findings | 99 records | 99 published records for Greensmith Home Inspection LLC include Electrical findings. |
| Home Inspection findings | 99 records | 99 published records for Greensmith Home Inspection LLC include Home Inspection findings. |
| Plumbing findings | 98 records | 98 published records for Greensmith Home Inspection LLC include Plumbing findings. |
| Foundation findings | 95 records | 95 published records for Greensmith Home Inspection LLC include Foundation findings. |
| Roof findings | 94 records | 94 published records for Greensmith Home Inspection LLC include Roof findings. |
| Pest findings | 88 records | 88 published records for Greensmith Home Inspection LLC include Pest findings. |
| Windows findings | 76 records | 76 published records for Greensmith Home Inspection LLC include Windows findings. |
| Sewer findings | 45 records | 45 published records for Greensmith Home Inspection LLC include Sewer findings. |
| Radon findings | 14 records | 14 published records for Greensmith Home Inspection LLC include Radon findings. |
| Mold findings | 13 records | 13 published records for Greensmith Home Inspection LLC include Mold findings. |
Topic counts describe records, not unique inspections, test results or the number of homes with a defect. A record may cover several topics. Record dates cover January 2022 to November 2026. 18 records use the upload date because no source-document date is available.
Where Greensmith Home Inspection has documented work
Documented record locations on Fresh House (as of November 22, 2026): 23 municipalities.
- St. Louis, MO (49 records)
- Florissant, MO (17)
- St. Peters, MO (7)
- Jennings, MO (4)
- O'Fallon, MO (4)
- Wentzville, MO (4)
- Ballwin, MO (2)
- Berkeley, MO (2)
- Chesterfield, MO (2)
- Fenton, MO (2)
- Ferguson, MO (2)
- Hazelwood, MO (2)
- St. Charles, MO (2)
- University City, MO (2)
- Arnold, MO (1)
- Creve Coeur, MO (1)
- De Soto, MO (1)
- Imperial, MO (1)
- Lake St. Louis, MO (1)
- Maryland Heights, MO (1)
- Normandy, MO (1)
- Troy, MO (1)
- Wright City, MO (1)
Quick answers about Greensmith Home Inspection
Who is Greensmith Home Inspection LLC?
Greensmith Home Inspection LLC is a home inspection company based in St. Louis, Missouri. As of November 22, 2026, Fresh House holds 110 documented records for Greensmith Home Inspection LLC at 106 properties, dated January 2022 to November 2026. 18 records use the upload date because no source-document date is available.
What inspection topics appear in Greensmith Home Inspection LLC records?
Published records for Greensmith Home Inspection LLC include HVAC, Electrical, Home Inspection, Plumbing, Foundation, Roof, Pest, Windows, Sewer, Radon and Mold findings. These are documented record topics, not a promise that every record covers every topic.
Do Greensmith Home Inspection LLC records include sewer findings?
Yes. Greensmith Home Inspection LLC has 45 published records with Sewer findings. This counts records mentioning the topic, not individual tests or positive results.
Do Greensmith Home Inspection LLC records include radon findings?
Yes. Greensmith Home Inspection LLC has 14 published records with Radon findings. This counts records mentioning the topic, not individual tests or positive results.
Do Greensmith Home Inspection LLC records include pest findings?
Yes. Greensmith Home Inspection LLC has 88 published records with Pest findings. This counts records mentioning the topic, not individual tests or positive results.
Are Greensmith Home Inspection LLC's original inspection reports published?
No. Original inspection reports are not shown publicly. This page shows the findings documented in those records.
Where does Greensmith Home Inspection LLC have documented records?
Fresh House records place its documented work in 23 municipalities, most often St. Louis (49 records), Florissant (17), St. Peters (7), Jennings (4) and O'Fallon (4). These are record locations, not a statement of the business's service area.
Which other professionals have records at the same properties as Greensmith Home Inspection LLC?
16 properties with Greensmith Home Inspection LLC records also carry records from Arch Air Services (HVAC), 10 from Drain Clean USA, LLC (plumbing), five from ASSURED HEATING AND COOLING (HVAC) and two from Electrical & Data Service Co. (electrical).
How to read this evidence
Fresh House publishes extracted findings from eligible source records and does not republish the original inspection reports on this profile.
Inspection observations do not establish that repairs or treatment were completed.
Services listed on the business profile are business statements, not proof that each service appears in the record history.
Record topics describe eligible records and do not establish current offerings, frequency, or credentials.
Documented property locations are not a claim about current service coverage.
18 records use a labeled upload-date fallback because no source-document date is available.
No license, certification, or other credential is inferred unless a verified issuer and identifier are present.
Services and record topics
HVAC findings
100 published records for Greensmith Home Inspection LLC include HVAC findings.
Electrical findings
99 published records for Greensmith Home Inspection LLC include Electrical findings.
Home Inspection findings
99 published records for Greensmith Home Inspection LLC include Home Inspection findings.
Plumbing findings
98 published records for Greensmith Home Inspection LLC include Plumbing findings.
Foundation findings
95 published records for Greensmith Home Inspection LLC include Foundation findings.
Roof findings
94 published records for Greensmith Home Inspection LLC include Roof findings.
Pest findings
88 published records for Greensmith Home Inspection LLC include Pest findings.
Windows findings
76 published records for Greensmith Home Inspection LLC include Windows findings.
Sewer findings
45 published records for Greensmith Home Inspection LLC include Sewer findings.
Radon findings
14 published records for Greensmith Home Inspection LLC include Radon findings.
Mold findings
13 published records for Greensmith Home Inspection LLC include Mold findings.
Stated coverage
The business profile states coverage as: St. Louis City, St. Louis County, Saint Charles County, Warren County, Jefferson County. This profile-stated coverage remains separate from the documented property locations above.
Contact Greensmith Home Inspection LLC
Home inspectorProfessionals documented at the same properties
Greensmith Home Inspection LLC records share properties with four other professionals on Fresh House. Each has a Fresh House profile showing its full documented work history.
- Arch Air Services, HVAC
16 shared properties · freshhouse.co/professional/arch-air-services
- Drain Clean USA, LLC, plumbing
10 shared properties · freshhouse.co/professional/drain-and-plumbing-service
- ASSURED HEATING AND COOLING, HVAC
5 shared properties · freshhouse.co/professional/assured-heating-and-cooling
- Electrical & Data Service Co., electrical
2 shared properties · freshhouse.co/professional/electrical-data-service-co
Inspections, repairs, photos, document what you know about a property.